14
A1120/40 Users Manual - Chapter 3
__________________________________________________________________________
Configuring the Modem
1. Connect a PC with HyperTerminal installed to the modem
2. Open the HyperTerminal software. Type the name of the connection in
the field provided
3. Press
OK
4. The dialogue opposite is displayed
5. Select the PC Port to which the GSM modem is connected
6. Press
OK
7. Enter the modem settings shown below
8. Disconnect the power
Modem Settings for ASL GSM Modem
Type the following commands to configure the modem:
ATQ0
<ENTER>
Quite mode off
ATE1
“
Echo on
AT&C1 "
Indicates remote carrier
AT&D0
"
Ignore DTR
ATS0 = 1
"
Answer after 1 ring
ATS10 = 50 "
Comms timeout
AT+CBST = 7,0,1 "
(These settings should be set by your service provider).
[Speed], [Name], [Connection Element]
AT+0 Speed
9600
N81
AT+1
9600
E71
AT+2
4800
N81
AT+3
4800
E71
AT+5
2400
N81
AT+6
2400
E71
AT+7
1200
N81
1200
E71
Once configured, remember to change HyperTerminal
baud rate to match.
ATE0 <ENTER>
Echo off
ATQ1
"
Suppress result codes
AT&W
"
Save settings
AT&V
"
View modem settings
©
Elster Metering Limited - M181 001 4A - 5/2007
DRAFT
Содержание A1120
Страница 2: ......
Страница 3: ...A1120 40 Programmable Electronic Polyphase Meter Chapter 1 Introduction M181 001 1B 5 2009 ...
Страница 4: ...Minor Change Record Date Modification 7 5 2009 Format change ...
Страница 7: ...A1120 40 Programmable Polyphase Meter Chapter 2 Operating Maintenance Instructions M181 001 2G 5 2010 ...
Страница 8: ......
Страница 52: ...44 A1120 40 Electronic Polyphase Meter Elster Metering Limited M181 001 2G 5 2010 Figure 3 Typical Nameplate ...
Страница 53: ...Operating Maintenance Instructions 45 Figure 4 Load Curves ...
Страница 70: ......
Страница 71: ......
Страница 73: ......
Страница 91: ......
Страница 156: ......