Art.-Nr./Art. No./Réf./N° art/N° art.: 900552
Version/Version/Version/Versione/Versión: 2.0
Datum/Date/Date/Data/Fecha: 25.05.2012 3/14
Safety sensor series 114...
Translation of the original operating instructions
1
In these operating instructions
The following standard models are described:
- 114262
- 114V62
- 114V62A0D
- 114270
- 114270A0D
For customer-specific sensors, the data sheets can also be requested from
elobau. The information specified in the data sheet applies for customer-
specific models if this information deviates from the operating instructions.
The person installing the safety sensor is to be provided with the operating
instructions.
The operating instructions must be kept in a legible condition and in an
accessible location.
Meaning of the symbols used:
2
Designated use
In combination with the elobau safety control units or similar safety controllers,
the safety sensors are exclusively used to monitor moving, isolating safety
devices.
The overall control concept in which the safety sensor is incorporated, must
be validated according to DIN EN ISO 13849-2 standards.
3
Approval according to UL / CSA
The following types are approved according to ANSI/UL 508 and
CSA C22.2#14-10:
4
Safety instructions
5
Warning against misuse
6
Exclusion of liability
No liability shall be accepted for damage and operational faults caused by a
failure to observe these operating instructions. All further liability of the
manufacturer is excluded in the case of damage caused by the use of
replacement and accessory parts that have not been authorised by the
manufacturer.
No unauthorized repairs, conversions and changes are permitted for reasons
of safety and the manufacturer shall not be liable for damage resulting
therefrom.
7
Function
A coded magnet safety sensor with a non-contact activation through a coded
magnet system. An elobau safety control unit or similar safety processing
unit / safety controller analyses the switching state of the sensor.
The safety sensors are suitable for the following elobau safety control units:
2-NO system (114262...):
471M41H31
2-NO system (114V62...):
46311.B1. / 47011.B1 / 471EFR.. / 471M41H31 / 485EP..
NO-NC system (114270...):
46212.E1. / 462121H... / 46312.B1 / 47012.B1 / 470121H1. / 470221E1U /
471EFR.. / 485EP..
8
Technical specifications
See 'Technical specifications' on page 10.
Warning
Failure to observe this warning may result in faults or
malfunctions.
Failure to observe this warning may result in personal injury
and/or damage to the machine.
Information
Indicates available accessories and useful additional
information
GB
- 114262
- 114270
- 114270A0D
- 114V62
3079760
CONFORMS TO
ANSI/UL 508
CERTIFIED TO
CAN/CSA C22.2#14
- Ensure that the safety sensors are only mounted and put into
operation by specially-trained and authorised personnel.
- Only install and put the device into operation once you have
read and understood the operating instructions and are familiar
with the applicable regulations on occupational safety and
accident prevention.
- The safety sensor may only be activated by the switching
magnet correctly mounted to the safety device. Actuation by a
spare switching magnet that is not mounted to the safety device
is prohibited.
- The safety sensors may only be operated in a perfect
functioning condition.
- Ensure that the safety sensors are exclusively used to protect
against risks.
- Ensure that all of the valid safety regulations for the respective
machine are complied with.
- Ensure that all of the valid laws and directives are complied with.
- Connecting sensors in series can, under certain circumstances,
reduce their performance level according to EN ISO 13849-1
standards due to a lower detection of errors.
- There are no known residual risks if all of the information
contained in these operating instructions is complied with.
- In case of incorrect or unintended use or manipulation, the use
of the safety sensors does not exclude risks to persons or
damage to machine or system components.
Please also observe the relevant information stipulated in the
DIN EN 1088 / ISO 14119 standards.
- Please ensure that when using safety control units that have not
been supplied by elobau, no current or voltage peaks which are
higher than the specified electrical data of the safety sensor are
generated by these devices. Current or voltage peaks may for
example be generated through capacitive or inductive loads.
- An exceeding of the electrical data of the sensor (e.g. in the
event of incorrect wiring or short-circuits) may cause irreparable
damage to the sensor.
- The sensor may only be activated in the approved control
options (see 'Technical specifications').
A non-compliance with this information may result in a reduced
sensor service life.