2.2.4 Remove the rear panel of the main Control Unit by undoing the three small fixing screws
(Note: be careful to retain these screws to screw back later)
.
2.2.5 Screw two side panels to “Control Unit” by 2 M10x45 screws. (do not tighten hard).
2.2.6 Plug in the side panel connectors (male-female) to the main Control Units (female-male) as
follows:
•
Left side-panel (female/DSUB25) – Plug in to the connector of the Control Unit
(male/DSUB25) and so plug in the other connector(male/DSUB9) to its counterpart on
Control Unit,
•
Right side-panel (male/DSUB25) – Plug in to the connector of the Control Unit
(female/DSUB25).
•
Connect the mains connector(AC 012) of the side-panel to its socket on the supply module.
Note: This WTMD is designed to prevent false connector/socket connection.
2.2.7 Replace the rear panel of the main Control Unit using the three small fixing screws previously
removed
(see 2.2.4 above)
.
2.2.8 Attach the back fixing crosspiece using the four remaining panel fixing bolts;
do not fully
tighten at this stage
.
2.2.9 Remove the four hex bolts holding the base fixing plate at the bottom of each side panel
using Allen key.
(Note: be careful to retain the hex bolts in a safe place for replacement later.)
2.2.10 Use two or more people to lift your WTMD carefully to a vertical position and move to
desired location. Ensure the two side panels are perfectly aligned parallel to each other with 76cm
spacing between panels.
CAUTION! The WTMD will not operate correctly if the side panels and the infrared
sensors are not properly paralleled.
2.2.11 Use two or more people to lift the WTMD to a vertical position and place on to the base
fixing plates ensuring the gateway is correctly orientated for the direction of the required
pedestrian traffic. Place the side panels to the base fixing plates, using Allen key
(see 2.2.9 above).
Tighten only to prevent moving; DO NOT over tighten.
2.2.12 Ensure that
ThruScan
is physically stable.
2.2.13 Fully tighten all bolts with the installation spanner.
2.2.14 Finally, ensure that the power cable is protected from pedestrian and vehicular traffic and
connect the power cable to the well grounded mains.
15