4. PROGRAMMING & SET UP
Programming and set up is performed as follows after the password is entered by
touch pads:
NOTE: Factory Settings Password for all
ThruScans
are “ 0000”.
NOTE: The password should only be known and entered by the authorized personal.
Only one person should hold responsibility for procedures requiring the password. The
operator should only be in charge of operating
ThruScan
and do the security control.
4.1 PROGRAM MENU
To enter the program MENU press the
SEL(
√
)
button once.
The LCD display will change to show:
“ENTER PASSWORD”
with
the 1
st
digit code number shown as
“0”
ENTER PASSWORD
[0 ]
To be able to enter the programming MENU the correct four-digit user code must now be entered
as follows:
1. Select the 1st digit of the user code by using the
UP&DOWN
buttons – Then press
SEL(
√
);
2. Select the 2nd digit of the user code by using the
UP&DOWN
buttons – Then press
SEL(
√
);
3. Select the 3rd digit of the user code by using the
UP&DOWN
buttons – Then press
SEL(
√
);
4. Select the 4th digit of the user code by using the
UP&DOWN
buttons – Then press
SEL(
√
);
If the correct code has been entered the display will change to
show:
“SECURITY LEVEL”
followed by the current security
level
set e.g.
“LEVEL 03”
SECURITY LEVEL
[03]
If the incorrect code has been entered the display will momentarily change to show:
“PASSWORD
ERROR”
and return to the normal operating display.
NOTE: Contact your dealer or the company with the serial number of your
ThruScan
or
your invoice information if you forget your password.
4.1.1 SECURITY LEVEL & SENSITIVITY LEVEL ADJUSTMENTS
ThruScan
s3-s9
:
Consisting of 10 separate security levels (channels), each security level (except for NC levels) can
be set to operate at a different sensitivity level. It is possible to adjust a total of 246 sensitivity
levels from security level 000 (the highest sensitivity) to 245 (the lowest sensitivity).
ThruScan
sX-sX-WP
:
Consisting of 20 separate security levels (channels), each security level (except for NC level) can be
set to operate at a different sensitivity level. 5 Fixed International Sensitivity Standard
(optional). It
is possible to adjust a total of 246 sensitivity levels from security level 000 (the highest sensitivity)
20