The default settings are designed to cover most eventualities without the need for adjustment.
However, if local situation or circumstances require fine tuning the sensitivity of any security level
(except NC) may be altered as follows:
1.
Once the correct user code has been entered the display will
turn to program mode and show the current security level. To
change the selected security level proceed with the following;
2.
Press the
SEL(
√
)
button once – The display will change to
show the current security level number in brackets e.g. [03],
3.
Select the required security level by using the
UP&DOWN
buttons – Then press
SEL,
4.
The display will change to show the current sensitivity setting
for that security level ;05] = 050,
5.
To change the sensitivity setting use the
UP&DOWN
buttons
until the desired setting is reached – Then press
SEL,
6.
The new sensitivity level will be stored and the display will
return to show the current security level number as in #1 above.
NOTE: The sensitivity setting on security level NC is fixed according to NILECJ – Level 2
and cannot be altered.
The above procedure can be repeated for each security level, by repeating points 2 – 5 as above
for any security level requiring to be designated.
When sensitivity adjustments are complete, other programming options may be accessed by
pressing the
UP&DOWN
buttons to select the required
sub
-MENU or press
RUN(X)
to return to
the normal operating mode.
4.1.2 SECURITY LEVEL AND SENSITIVITY LEVEL, ZONE ADJUSTMENTS
(
*for
ThruScan
sX/sX-i/sX-WP
)
The detection areas for
ThruScan
are divided into 3 sections; such as bottom zone(ZONE 1),
middle zone (ZONE 2) and top zone (ZONE 3). Exclusively the sensitivity level of
ThruScan
can be
adjusted separately in each zone. i.e. / the middle zone of
ThruScan
may be adjusted to be more
or less sensitive in comparison to top or bottom zones.
By this feature, the sensitivity level of zone 2 in which there would more likely be keys, cellular
phones, belts etc. can be decreased while the other zones’ can be increased.
SECURITY LEVEL
LEVEL [03]
SECURITY LEVEL
LEVEL [05] = 050
SECURITY LEVEL
INDIVIDUAL ZONE SENS
LEVEL [03]
ZONE [01]
This procedure may be altered as follows;
1- Set the Security Level Adjustments as explained in 4.1.1. After this
procedure, press the
SEL(
√
)
button, and the display on the right side
will appear.
2- Select the desired zone using
Up&Down
buttons and then press the
SEL(
√
)
button .
3- Adjust the desired sensitivity level on the new display. Then press the
SEL(
√
)
button .
4- Repeat the procedures in steps 2 and 3 for other zones. After the Sensitivity assignment
procedures, press
RUN(X)
button to exit from the MENU and to start.
23