5
Troubleshooting
17
18
19
5204
972
X1
2 1
18
17
19
NTC HIGH TEMP
The programme unit indicates a short-circuit
with the temperature sensor or the tempera-
ture exceeds 98°C.
Try to restart the machine (i.e. reset the error
code) by pressing START.
1. Undo the temperature sensor connections and
measure the resistance of the sensor. The resistance
should be as in the table below:
Approximate values for a fully functional
temperature sensor
T (°C)
R (ohm)
19
6109
20
5844
21
5592
22
55
2
5124
Resistance OK
Incorrect resistance
The temperature sensor is probably
defective.
2. Reset the connection on the sensor and exit the
programme using
a
. Enter the service programme
and read the temperature. Disconnect one of the
inputs 1 and 2 on card switch X1. Verify that the display
window shows 0°C.
Yes
No
Incorrect temperature sensing on the
programme unit card.
Incorrect cabling to the temperature sensor. Verify
and replace if necessary.
Temperature sensor
Temperature indication
SERVICE PROGRAM
LEVEL
2
TEMP
22°C
SPEED
0
DRAIN CLOSED
YES
EMERGENCY STOP
DOOR LOCKED
TEMPORARY PAUSE
DOOR CLOSED
OIL
REMOTE START
IMBALANCE
SERVICE
PHASE CHECK
Содержание W4400H
Страница 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Страница 2: ......
Страница 6: ... ...
Страница 14: ...14 ...
Страница 18: ...18 ...
Страница 64: ...64 ...
Страница 72: ...72 ...
Страница 146: ...146 ...
Страница 164: ...164 ...
Страница 166: ...166 ...
Страница 185: ......
Страница 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...