8
Troubleshooting
NO HEATING
The temperature has not increased the number
of degrees specified in the function MIN ALLO-
WABLE TEMPERATURE INCREASE (see set-
tings 2) during the time that is programmed in
the function MAXIMUM HEATING TIME (Confi-
guration 1).
If the power is on, be very careful when
working on the machine.
Try to restart the machine (i.e. reset the error
code) by pressing START.
If the error returns, first make sure that:
• the programme module is not incorrectly pro-
grammed
• the heat supply is intact, the steam boiler is
operating
• the drain does not leak.
1. Exit the programme using
a
. Enter the service
programme and fill up water to above the safety le-
vel (5-10 cm above the lower edge of the inner drum).
Switch on the heating. Does the steam valve open?