11
12
13
X5
97
X6
12
11
13
4128
Troubleshooting
DOOR UNLOCKED
No signal from the ”Door locked” during pro-
gramme operation.
If the input signal for the "Door locked" is lost
during programme operation, the "DOOR UN-
LOCKED" error code is immediately genrera-
ted.
At programme start, this error code is sup-
pressed for a few seconds.
If the power is on, be very careful when
working on the machine.
1. Try to restart the machine (i.e. reset the error code) by
pressing START.
Error message returns
No error message
Temporary error in the door
lock or programme unit
2. Exit the programme using
a
. Enter the service
programme and verify that there is voltage between
X5:2 - 6 when the door lock is engaged.
No voltage
Voltage present but black
square does not light
I/O card 1 A11 probably
defective
3. Verify that there is voltage supply between X5:1 - 5
when the door lock is switched on.
Voltage present
No voltage
Troubleshoot the cabling for
the voltage supply (between
the main power switch Q1
and X6).
4. Is the lock command present? Measure X:92 on the
door lock controller.
Yes
No
Troubleshoot according to
the error codes in section
29.
Troubleshoot cabling between X5 and the actuator. The
actuator could be defective.
Indication
Door locked
SERVICE PROGRAM
LEVEL
2
TEMP
22°C
SPEED
0
DRAIN CLOSED
YES
EMERGENCY STOP
DOOR LOCKED
TEMPORARY PAUSE
DOOR CLOSED
OIL
REMOTE START
IMBALANCE
SERVICE
PHASE CHECK
Switch cam
Microswitch S
Lock solenoid and
microswitch S4
Lock pin
Lock plate
Содержание W4400H
Страница 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Страница 2: ......
Страница 6: ... ...
Страница 14: ...14 ...
Страница 18: ...18 ...
Страница 64: ...64 ...
Страница 72: ...72 ...
Страница 146: ...146 ...
Страница 164: ...164 ...
Страница 166: ...166 ...
Страница 185: ......
Страница 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...