178
Weighing equipment (Optional equipment)
21
����
����
�����
����
����
����
���
�
���
�
���� ����
�����
����
�����
����
�����
����
����� ����
�����
����
�����
����
�����
����
��
21
6075
To replace the scale unit
• Remove the machine’s left-hand rear side panel.
• Disconnect the six connectors to the scale unit.
• Take the scale unit off its mounting plate.
• Install the new scale unit, assembly in reverse order of disassembly.
•
Check that the dead load selector is set to
1000-1400 kg
for W4400H,
2100-2550 kg
for W850H, W1100H and
1200-1600 kg
for W600H.
• Calibrate the weighing equipment, see “Calibrate the scale” under
“Machine operation”.
Connectors,
load cells
Dead load selector
Scale unit
Connector, power
supply
Connector,
CPU communication