114
Programme unit
Settings 2
In Configuration 2, there are variables that, in case of carelessness or
lack of knowledge, may affect the safety systems or operating safety
of the machine. Because of this, these variables are protected by a
code system. Each time a variable needs to be changed, it is neces-
sary to obtain a new code from the manufacturer.
The following variables are available in
Configuration 2
:
ERROR, START NOT ALLOWED
ERROR, MIS COMMUNICATION
ERROR, EWD INTERLOCK
ERROR, I/O COMMUNICATION
ERROR, LOW OIL LEVEL
ERROR, LOW OR HIGH VOLTAGE
ERROR, ERROR CODES FROM MOTOR
ERROR, PRESS. SENSOR TILT
ERROR, PRESSURE SENSOR TIMEOUT
ERROR, DOOR SWITCH TILT
ERROR, LEVEL OFFSET
ERROR, LEVEL SYSTEM NOT CALIB.
TIME DELAY BEFORE DOOR OPENING
UPPER TEMPERATURE FOR ERROR
LOWER TEMPERATURE FOR ERROR
MAX ADJUST TEMPERATURE
MAXIMUM EXTRACT SPEED
DEFAULT WASH SPEED
DISTRIBUTION SPEED 1
DISTRIBUTION SPEED 2
DEFAULT LOW EXTRACT SPEED
DEFAULT MEDIUM EXTRACT SPEED
DEFAULT HIGH EXTRACT SPEED
START EXTRACT SPEED
DEFAULT WASH ACCELERATION
DISTRIBUTION ACCELERATION
RETARDATION ACCELERATION
EXTRACT ACCELERATION
START EXTRACT ACCELERATION
EXTRACT RETARDATION
MAX SPEED DURING FILLING
MAX LEVEL OFFS. FOR AUT. CALIB.
TIME AT DISTRIBUTION SPEED 2
NUMBER OF REDIST LOW 1 UNB.
NUMBER OF REDIST LOW 2 UNB.
NUMBER OF REDIST MEDIUM UNB.
NUMBER OF REDIST HIGH UNB.
NUMBER OF REDIST EXTREME UNB.
DRAIN TIME AT PROGR. START
DRAIN TIME AT PROGR. END
READY
HEATING RELAY ON IF NOT HEATED
TEMPERATURE INCREASE ALLOWED
LEVEL EMPTY
LEVEL OVERFILL
PAUSE TEST LEVEL
PAUSE TEST TEMPERATURE
DEFAULT TEMPERATURE HYSTERIS
TEMPERATURE STEP IN COOL-DOWN
DEFAULT LOW EXTRACT TIME
DEFAULT MEDIUM EXTRACT TIME
DEFAULT HIGH EXTRACT TIME
DEFAULT DRAIN TIME
DEFAULT DISTR. TIME
DO UNBALANCE MEASUREMENT
DRAIN OPEN DELAY
START EXTRACT TIME
ROLLOUT TIME
PAY PER WASH ALARM
LOCK TEST DELAY
DRAIN TIME WHEN OVERFILL
OIL LUBRICATION HOURS
PULSE TIME OIL LUBR. SEC
AMOUNT OF I/O MODULES (1-)
DELAY CLEAR DOOR TEXT
TIMEOUT DRAIN AT PROGRAM START
TIMEOUT DURING PAUSE
MINIMUM TEMPERATURE INCREASE
DOOR OPEN DELAY FOR MOTOR LOST
ERROR, NO WATER
ERROR, OPEN DOOR
ERROR, DOOR LOCK
ERROR, LOW TEMPERATURE
ERROR, HIGH TEMPERATURE
ERROR, WATER IN MACHINE
ERROR, NO HEAT
ERROR, REMAINING WATER
ERROR, UNBALANCE SWITCH
ERROR, MOTOR COMMUNICATION
ERROR, LEVEL ADJUST
ERROR, EMERGENCY STOP
ERROR, WEIGHT FROM SCALE
ERROR, DOOR LOCK SWITCH
Содержание W4400H
Страница 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Страница 2: ......
Страница 6: ... ...
Страница 14: ...14 ...
Страница 18: ...18 ...
Страница 64: ...64 ...
Страница 72: ...72 ...
Страница 146: ...146 ...
Страница 164: ...164 ...
Страница 166: ...166 ...
Страница 185: ......
Страница 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...