60
Troubleshooting
36
36
5950
X11
X11
M1
UNDER VOLTAGE
The motor controller indicates the DC level is
too low.
If the power is on, be very careful when
working on the machine.
Switch off the machine for at least 0 seconds
to ensure the motor controller has been comple-
tely reset. Then try to start the machine again. If
the error returns, troubleshoot as follows:
1. Verify the voltage supply (230/400 V) to the motor
controller at the contactor X311.
Voltage too low
Voltage OK
The motor controller is
probably defective.
2. Inspect the power supply (230/400 V) at the main
power switch Q1 on the machine.
Voltage too low
Voltage OK
Defective cabling
.