Troubleshooting
List of errors, functions monitored and relevant error messages displayed
Error/Function
Error message displayed
01 ERROR. NO WATER
Water level has not reached set level within time set.
NO WATER
After this error message appears and the machine is reset,
the machine will try again.
02 ERROR. OPEN DOOR
Signal from microswitch which checks door status absent during program.
After this error message appears and the machine is reset,
the machine will try again.
DOOR OPEN
03 ERROR. DOOR LOCK
Signal from microswitch which detects when the door is locked
absent during program.
DOOR UNLOCKED
04 ERROR. LOW TEMPERATURE
The temperature is below the lowest value allowed (open circuit in
temperature sensor).
NTC LOW TEMP
05 ERROR. HIGH TEMPERATURE
The temperature is above the highest value allowed (short-circuit in
temperature sensor).
NTC HIGH TEMP
06 ERROR. WATER IN MACHINE
The water level is higher that the level EMPTY at the start of the program. WATER IN DRUM
07 ERROR. OVER-FILLED
The water level is higher than the ”LEVEL OVERFILL” (i.e. DRUM
OVER-FILLED) level. If this function is switched off (=N), instead the
drain valve will open for a short time and discharge some of the water.
This is described under the function ”DRAIN TIME WHEN OVERFILL”
(i.e. DRAIN TIME AFTER OVER-FILLING) earlier in this section.
MACHINE OVER-FILLED
08 ERROR. NO HEAT
The temperature has not increased by the number of degrees specified in
the function ”MIN. TEMPERATURE INCREASE” (see back in this
section), over the period of time specified in the function MAXIMUM
HEATING TIME (see ”SETTINGS 1”).
NO HEATING
10 ERROR. REMAINING WATER
When the drain sequence has finished, the water level is still higher than
the EMPTY level.
NOT DRAINED
11 ERROR. UNBALANCE SWITCH
The unbalance switch is closed when the machine is starting on a drain
sequence.
UNBALANCE SENSOR FAULT
13 ERROR. MOTOR COMMUNICATION
Communication between PCU and motor control unit interrupted or
disturbed.
NO MOTOR COMM
14 ERROR. LEVEL ADJUST
Every machine has individual level calibration at the factory. If these
calibration values are missing or fall outside the limit values, an error
warning will be flagged at each program start-up. The program can still be
started, however, by pressing START. It will then use standard (default)
values, which means that the levels will not be as precise as intended.
LEVEL CALIBRATION
Содержание W4400H
Страница 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Страница 2: ......
Страница 6: ... ...
Страница 14: ...14 ...
Страница 18: ...18 ...
Страница 64: ...64 ...
Страница 72: ...72 ...
Страница 146: ...146 ...
Страница 164: ...164 ...
Страница 166: ...166 ...
Страница 185: ......
Страница 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...