F.2
Alarms and Warnings
Anomaly
Type of
anomaly
Description
Possible
causes
Instructions to User
Action for Service*
N°323
ACF
Warning
Air filter absent,
micro-switch
AFS.
- Filter not
present.
- Micro-switch
AFS interrupted.
Air filter absent, it is pos-
sible that this causes
damage to internal elec-
tric and electronic
components. Refit the
filter.
Check filter microswitch
connections
Check cable integrity; Check X45
on ACU E.4
N°200
ACUM
Stops
machine.
ACU not
identified.
- Issue with the
communication
cable/connec-
tors between
ACU and UI.
- Communica-
tion cable failure.
- ACU failure.
Communication error
with electronic board.
Switch off and on the
appliance.
If the warning persists,
call Service.
Restart the oven. Check commu-
nication cable integrity and check
continuity on 8-poles connector
between UI and ACU. Check J7
or J8 on UI TOUCH E.2
Check J1 or J2 on UI DIGIT E.3
Check X27 (one of A-B-C-D) on
ACU E.4
Upload again the software.
Replace ACU.
N°116
ACSS
Blocks
machine;
fatal error.
ACS software
version (inside
ACU board)
incompatible
with present UI
SW version.
Wrong software
upload (exam-
ple: after
replacing ACU
board, the sw is
not uploaded).
ACS software version
(inside ACU board)
incompatible with present
UI SW version.
Call Service.
Upload correct software to pro-
gram the ACU after its
replacement.
N°115
ACUS
Blocks
machine;
fatal error.
ACU software
version (main
uC) incompati-
ble with present
UI SW version.
Wrong software
upload (exam-
ple: after
replacing ACU
board, the sw is
not uploaded).
ACU software version
(main uC) incompatible
with present UI SW
version.
Call Service
Upload correct software to pro-
gram the ACU after its
replacement.
N°292
ASCH
Warning
Component
compartment
temperature
warning (NCC).
- Air intake filter
is dirty.
- Too high room
temperature.
Check room temperature
considering the oven
needs fresh air to cool
electronic compartment.
Clean air intake filter.
Allow oven to cool before
cooking.
If the warning persists,
call Service.
Activates at 65
℃
. Check room
temperature considering the oven
needs fresh air to cool electronic
compartment. Clean the filter.
Check inner lack of cavity insula-
tion/other heat transmissions
from cavity to electronic compart-
ment. If needed fix it.
N°110
bAtt
Warning
Battery is low.
Ageing
Call Service to replace
battery.
Replace the CR2032 type battery
on the UI.
E.2
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...