98
Anomaly
Type of
anomaly
Description
Possible
causes
Instructions to User
Action for Service*
N°325
GrCo
Stops
machine
in
cleaning.
Grease collec-
tor valve
opened.
Misuse
Ensure to close the
grease collector drain
valve before restarting
the cleaning cycle.
Check micro-switch and mecha-
nism on the ball valve under the
oven.
Check wire continuity from micro
to ACU.
N°282
Hd01
Both boiler
and boiler-
less: stops
cleaning.
For boiler
less stops
humidifi-
cation
For boiler
Stops
humidifi-
cation and
combi
cycles
under
100
℃
Water solenoid
valve EV1 not
working.
Switch the oven Off/On.
If the error persists, man-
ually clean/rinse the
oven cavity and call
Service.
Instant steamer not working. For
Service, check X2 (see “Power
board (ACU)“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
N°254
Hd02
Warning
Water solenoid
valve EV2 not
working
Quenching
valve.
Switch the oven Off/On.
If the error persists, man-
ually clean/rinse the
oven cavity and call
Service.
The steam exhaust management
system does not work. Insert 0.2
L of water from the outlet air duct
to avoid duct overheating. Serv-
ice, check X2 (see “Power board
(ACU)“ section in “Detailed appli-
ance and components
description/functioning“ chapter
of the proper Service manual).
N°326
Hd03
Stops
machine.
Cavity drain
valve BV3 not
working.
Switch the oven Off/On.
If the error persists, man-
ually clean/rinse the
oven cavity and call
Service.
Cavity drain valve not working. It
is impossible to use the machine.
For Service, check X2 (see
“Power board (ACU)“ section in
“Detailed appliance and compo-
nents description/functioning“
chapter of the proper Service
manual).
N°228
Hd05
Stops
cleaning,
cooking
cycles,
excluding
convection
and combi
under
100
℃
Water solenoid
valve EV5 not
working. Boiler
fill solenoid
valve.
Switch the oven Off/On;
If the error persists, it is
possible to cook in con-
vection mode or in combi
under 100
℃
mode. Auto-
matic cleaning not
working: manually clean/
rinse the oven cavity and
call Service to restore full
functionality.
boiler filling not working. For
Service, check X5 (see “Power
board (ACU)“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
N°229
Hd06
Stops
cleaning.
Boiler drain
valve BV6 not
working.
Switch the oven Off/On.
If the error persists, man-
ually clean/rinse the
oven cavity and call
Service.
boiler drain valve not working.
Cleaning impossible. For Service,
check X5 (see “Power board
(ACU)“ section in “Detailed appli-
ance and components
description/functioning“ chapter
of the proper Service manual).
N°261
Hd07
Stops
cleaning.
Water solenoid
valve EV7 not
working.
Switch the oven Off/On.
If the error persists, man-
ually clean/rinse the
oven cavity and call
Service.
Cavity water inlet valve not work-
ing. Cleaning impossible. For
Service, check X3 (see “Power
board (ACU)“ section in “Detailed
appliance and components
description/functioning“ chapter
of the proper Service manual).
N°264
Hd08
Stops
cleaning.
Cleaning pump
M8 not working.
Switch the oven Off/On.
If the error persists, man-
ually clean/rinse the
oven cavity and call
Service.
Recirculation pump. Cleaning
impossible. For Service, check
X3 (see “Power board (ACU)“
section in “Detailed appliance
and components description/
functioning“ chapter of the proper
Service manual).
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...