43
HOW TO UPDATE:
In the previous chapter D.3.3
Software update Level T, K (Touch screen)
we have explained were to locate the
P.F.
in the PRIDE /
AGELUX web site and how to unzip/save into your USB key in the root.
• Once that the USB key has been prepared in the correct manner and for the specific PNC appliance:
Turn OFF the oven.
Insert the USB key
with
P.F.
installed in
root.
Turn OFF the oven.
The oven will update; follow display instructions /
Extract the USB key without turning OFF the
oven when requested.
The oven will automatically reboot and install the application; on the display will appear a pop up indicating the operation is in
progress.
The software will update the
UI, ACU electronic boards
.
The
P.F.
installation will NOT erase the recipies of the customer nor change any personalization, parameters and so on; a software
update will update the application, not the parameters!
NOTE!
• In case of power loss during installation, in case of extraction of the USB key during installation or other manoeuvre
error, don't worry; The update process can be restarted again without damaging the appliance.
• In case of errors or problems with the detection of the USB key, upload the software into another type of USB key
(manufacturer/dimension size) it could be that some USB key manufacturers cannot be read by the oven.
D.3.3.5 Programming Parameters upload (Parameters Upload)
CAUTION
By loading the programming parameters, the oven is NOT COMPLETELY SET TO THE
FACTORY VALUES. The Untouchable parameters are not changed anymore. Refer to Technical
Bulletin PDD2020-12.
The Programming parameters (that from now on we will call
P.P.
as abbreviation) is the complete parameter list.
The parameters contained in each list/appliance are more than 400, but only a fraction of the parameters can be set by “hand“ in the
Service area by scrolling in the parameter list and manually changing the value. The “hidden“ parameters are for factory eyes only,
they are algorithms or sensible values (any unnecessary change could block / jam permanently the electronic board).
In case of need to update a complete parameter list it will be necessary to download locally the
P.P.
and then upload the
P.P.
into the
oven via USB key.
WHEN TO UPDATE:
• always after any software update (
P.F.
programming file upload);
• in case of any spare part replacement (UI, ACU)
HOW TO UPDATE:
In the previous chapter D.3.3
Software update Level T, K (Touch screen)
you have located the
P.P
on the PRIDE web site / AGELUX
web site.
• Double click to unzip and locally save the
P.P.
into your USB key in the root.
Appearance of the
P.P.
when unzipped and
locally saved on your USB key in root.
• Insert the freshly made USB key into the access USB port of the oven.
• Follow instructions in how to enter into the D.3.2.3
USB transfer ambient (Service functions)
with “Service credentials“.
• Enter into the “Upload selection“; select the
P. P
(411404500 - this number change according to type of oven) that you have
downloaded and saved into your USB key that you desire to transfer from the USB key into the oven UI and press
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...