D.3.2.1 Data Monitor
Once logged as SERVICE, in the sub menu is available the “Data Monitor“ from where is possible to see all temperatures and status
of the oven.
NOTE!
To exit from Data Monitor menu, tip on any area of the screen except the “prev page“ button.
D.3.2.2 By-Pass environment
Once you are logged as Service D.3.1
the By-Pass environment is automatically available in the
secondary menu of the home page.
From this environment it is possible to:
Manually activate the following devices:
• Cavity “pwm“ (this is the cavity gas burner, but is necessary to activate also the cavity fan rpm).
• Boiler “pwm“ (boiler burner).
• Cavity fan rpm (this is the cavity fan).
• Cavity flap venting valve “VV1“ (cavity air intake).
• Cavity drain valve (“BV3“).
• Boiler drain valve (“BV6“).
• The valves EV1-EV2-EV4-EV5-EV7-EV10-EV11-EV12.