80
Ref.
Group
Pin
Direct.
Function
X20
Temper.
– NOT USE –
X21
Temper.
– NOT USE –
X22
Temper.
1
IN
TQS
Quenching system thermocouple
2
IN
X23
Temper.
1
IN
TAR
Aromatizer thermocouple
2
IN
X24
Lambda sensor
X25
Boiler level
1
IN/OUT
SL
Boiler safety level detection probe
2
IN/OUT
WL
Boiler working level detection probe
3
IN
REF
Boiler level detection probes reference
X27-A
IN/OUT
PMACS
communication BUS
X27-B
IN/OUT
PMACS
communication BUS
X27-C
IN/OUT
PMACS
communication BUS
X27-D
IN/OUT
PMACS
communication BUS
X28-A
IN/OUT
PMACS
Recovery communication BUS
X28-B
IN/OUT
PMACS
Recovery communication BUS
X29
24V
1
IN
+24V
dc
2
IN
3
IN
0V
dc
4
IN
X30
Cavity SSR
1
OUT
KC1
Cavity 1 solid state relay
2
OUT
KC2
Cavity 2 solid state relay
3
OUT
4
OUT
5
OUT
0V
dc
X31
Boiler SSR
1
OUT
KB1
Boiler 1 solid state relay
2
OUT
KB2
Boiler solid state relay
3
OUT
4
OUT
5
OUT
0V
dc
X32
Cooling Fan 1
1
OUT
FAN1
Cooling fan 1 power supply 24Vdc
2
IN
FAN1
Cooling fan 1 tachometer sensor
3
OUT
FAN1
Cooling fan 1 speed control
4
OUT
FAN1
Cooling fan 1 0Vdc
X33
Cooling Fan 1
[ONLY 6/1 OVEN]
1
OUT
FAN1
Cooling fan 1 power supply 24Vdc
2
IN
FAN1
Cooling fan 1 tachometer sensor
3
OUT
FAN1
Cooling fan 1 speed control
4
OUT
FAN1
Cooling fan 1 0Vdc
X35
Vent. Valve
1
OUT
VV1
Venting valve 1 clockwise rotation
2
OUT
N
3
OUT
VV1
Venting valve 1 counter clockwise rotation
X36
– NOT USE –
X37
KS
1
OUT
KS
Safety contactor
2
X38
Smoker
1
OUT
N
2
OUT
R1
(Smoker heating element)
3
OUT
4
IN
X39
Flow meter
1
2
OUT
FM
Flow meter reference
3
IN
FM
Flow meter feedback
X40
Temper.
1
OUT
NCC
NTC cabinet components
2
IN
3
OUT
NM8
NTC pump M8
4
IN
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...