72
T
ouch
Digit
Parameter
ID
Mnemonic
Short Description
T
able
Min
Max
Default
1
1
378
OMbU
Offset PWM max power upper
boiler burner
0
5
0
1
1
379
IndL
Index for boiler level sensing
sensitivity
1
5
1
1
0
381
bPHt
Boiler temperature to be kept
in stop mode
0
99
84
1
1
408
tPrn
User HACCP data log sample
time.
60
3600
60
1
1
410
PdtE
Delta temperature to stop the
preheating in advance for tem-
perature lower than 100
℃
0
100
20
1
1
415
dtCP
Cleaning pre-cool set point
delta
0
50
10
1
0
416
FCLP
Cleaning – powder (factory
settings)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
0
417
StF
Show display touch feedback
on screen
{0, “Disabled“}
{1, “Enabled“}
0
1
0
1
0
418
rECt
Minimum recovery tempera-
ture and humidity time
(Automatic cycles only)
0
600
20
1
1
419
CdEt
Cool down extension timeout
0
600
60
1
0
421
dSPr
Enable the water spray compo-
nent (factory setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
0
1
0
423
SHMF
Skyhub – configuration man-
agement: add and delete
(factory setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
426
dISG
Boost duration for ISG when
no boiler
0
250
5
1
0
433
AtHa
Water hardness expressed in
french degrees
0
100
10
1
0
434
SdL
Defines what kind of link will be
used for Skyduo connection: it
can be through connectivity
HUB or direct link between
appliances
{0, “HUB“}
{1, “Direct link“}
0
1
0
1
1
437
CbLH
Water level probe higher
threshold
0
2000
1200
1
1
438
CbLL
Water level probe lower
threshold
0
2000
600
1
0
439
FSIP
Enables the possibility to
create messages to be dis-
played during programs
execution (factory setting)
{0, “Disabled“}
{1, “Enabled“}
0
1
1
1
1
441
bSLA
Sets if the boiler works with
single or dual levels detection
{0, “Dual“}
{1, “Single“}
0
1
0
1
1
442
SCtE
Setpoint for components com-
partment temperature
0
200
45
0
1
443
SLO
Sets the inactivity time,
expressed in seconds, after
which the door LED lamps are
turned off. Set 0 to disable this
function.
0
3599
900
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...