86
Anomaly
Type of
anomaly
Description
Possible
causes
Instructions to User
Action for Service*
N°260
Cdo
Stops
cleaning
Cleaning
drawer absent
(DRS).
The cleaning
drawer has not
been inserted or
properly
inserted in its
housing;
The detection
devices
(magnet/mag-
netic reed) have
issues.
The oven can continue to
cook but cleaning cycle
could not be performed
until the drawer will be in
place; Ensure that the
cleaning drawer is in its
housing and inserted
properly in order to trig-
ger the detection
devices; If the error per-
sists, clean/rinse the
oven manually . If the
problem persists, clean
the oven manually and
call Service.
Check the microswitch is con-
nected on wiring harness; Check
harness continuity; Check X48 on
ACU (see E.4
section;
Replace microswitch (see “Dis-
penser rinse aid“ section in
“Servicing the appliance“ chapter
of the proper Service Manual.
N°294
CFbL
Warning
Cooling fan
stopped (FAN1-
2-3).
Cooling fan
motor overload
due to dirt or
oxidation;
Other electric /
mechanical
issue.
The oven will be opera-
tive until the components
compartment will reach a
critical temperature.
Check for any object stopping the
fan; Check cooling fan is 24V fed
from X32, X33 or X34 on ACU
(seeE.4
section);
See “Cooling fan, FAN1“ section
in “Detailed appliance and com-
ponents description/functioning“
chapter of the proper Service
manual).
N°310
CntC
Stops
machine.
Cavity SSR
NTC failure
(NTC3).
- Connector
failure.
- TC sensor
failure.
- ACU failure.
Call Service.
Cavity SSR temperature sensor
damaged.
Check NTC wire/connector con-
tinuity X41 on ACU (see E.4
U Level T ,K, B, C (Power Board)
section.
Check impedance is 10kOHM at
25
℃
: if not replace NTC
N°203
CPUA
Stops
machine.
ACS micro
does not
communicate.
ACU failure.
ACS IC broken on ACU.
Replace ACU.
See “Power board (ACU)“ section
in “Detailed appliance and com-
ponents description/functioning“
chapter of the proper Service
manual.
N°204
CPUt
Stops
machine.
TC microproc-
essor does not
communicate.
ACU failure.
TC IC broken on ACU.
Replace ACU. (see “Power board
(ACU)“ section in “Detailed appli-
ance and components
description/functioning“ chapter
of the proper Service manual).
N°312
CSHt
Warning
Cavity SSR
NTC overtem-
perature
(NHSC).
- Inlet air filter
dirty.
- Cooling fan
failure.
- Cooling inlet
air sucking
warm/hot air.
- Oven installed
by hot machines.
- Steam/Heat
leakage in the
electronic
compartment.
- SSR internal
issue.
Do not switch the oven
OFF. Wait for the temper-
ature to decrease. Clean
the air inlet filter. Check
with a thin strip of paper
whether a consistent air
flow can be detected at
the cooling air inlet.
Check if the inlet cooling
air may be affected by
heat produced in the
kitchen (in case the oven
is located by hot units,
stop working with those
units).
If the error persists call
Service.
Activates at 85
℃
/Reset at 75
℃
.
Check room temperature consid-
ering the oven needs fresh air to
cool electronic compartment.
Clean the air intake filter. Check
inner lack of cavity insulation/
other heat transmissions from
cavity to SSR. If needed fix it.
Verify heat sink integrity.
Check X41 on ACU E.4
Level T ,K, B, C (Power Board)
Change thermal pad ;
Replace SSR. (see “Electric com-
ponents assembly“ section in
“Servicing the appliance“ chapter
of the proper service Manual).
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...