77
E.3
UI Level B, C (Digit)
If the user interface (user board) cannot communicate with any other board for more than a determinate time (for example 15 sec)
any running cooking cycle will be stopped. The error icon will show a message “
ECom
“. No cooking cycle can be launched till the
communication is established again.
CONNECTOR
FUNCTION
NOTES
BT1
BATTERY CR2032
DATE / TIME MEMORY
J1
PMACS
J1 IS CONNECTED TO ACU (POWER BOARD) X27.
Pins of J1:
= J1-1 = RS485 J1-2 = RS485 J1-3 = GND
J1-4 = +12V J1-5 = GND
J2
PMACS
see note
J3
ADDRESS
NOT USED / EMPTY
J4
ON / OFF
12V AND 0/1 SWITCH STATE
J5
USB
USB PORT
J6
NIU
FOR WIFI ANTENNA
J7
DEBUG
NOT USED / EMPTY
J8
BOARD PROGRAMMING
NOT USED / EMPTY
X21
COMMUNICATION CABLE
12V AND 0/1 SWITCH STATE
X19
PHASE 230V IN, CONNECTED TO C1.1 and C1.2 of EWD “SM“
RECOVERY
CONNECTED TO ACU (POWER BOARD) X28
NOTE!
The J1/PMACS can be connected to any X27 connection of the ACU. J1 vs J2 are interchangeable. X21 and X19 are
the numbering of the ON/OFF board, but also the ACU has the same numbering.
ACU-X27
BT1
J2
J1
J5
J6
J4
J3
J8
J7
X21
X19
J5
RECOVERY
ACU/X28
USER BOARD
(U.I)
O/I ON OFF
BOARD (SM)
Содержание MAGISTAR OVEN 6-10-20GN
Страница 16: ...16 C 5 Equipment modules and interactions ...
Страница 46: ...46 PRESS and HOLD on PNC field PRESS and HOLD on PNC field 2 3 4 5 6 7 ...
Страница 57: ...57 D 4 2 6 HACCP log HACP LOG Once entered into the dedicated Service area scroll until ...
Страница 58: ...58 D 4 2 7 Programs chef recipes PrOG Once entered into the dedicated Service area scroll until ...
Страница 59: ...59 D 4 2 8 Alarm log ALrM LOG Once entered into the dedicated Service area scroll until ...
Страница 123: ......
Страница 124: ...Electrolux Professional SPA Viale Treviso 15 33170 Pordenone www electroluxprofessional com ...