Electronic Control
3-24
Test 8:
Test 9:
Test 10:
Test 11:
Test 12:
Test 13:
Test 14:
Test 15:
Test 16:
No. Replace the motor.
Yes. Go to step (2)
No. Check the tub bearings.
Yes. Go to step (3)
If readings are correct, check wiring from motor to
motor control board, If good, replace motor control
board. If the readings are incorrect, replace motor.
No. Replace the motor.
Yes. Go to step (2)
No. Check the tub bearings.
Yes. Go to step (3)
If meter reads other than between 105 & 130 Ohms,
replace the motor. If reading is between 105 & 130
Ohms, Go to step (4)
If the readings are correct, replace motor control
board. If the readings are incorrect, replace motor.
Wiring bad, correct wiring problem.Wiring good,
replace main control board. If problem is not
corrected,replace the motor control board.
Wiring bad, Correct wiring problem. Wiring good,
Replace the user interface board. If problem is not
corrected, replace the main control board.
If correct, for error code E5C, replace motor control
board. If correct, for error codes EA1, EA2, EA3,
EAE or EA5, replace main control board
If readings are incorrect, replace heating element.
If readings are incorrect, replace the heating
element. If problem is not corrected, replace main
control board.
No, replace the heating element.
Yes, check the wiring.
If good , replace the motor control board.
Yes. Switch the hoses to correct position
No. go to step 2
Yes. Fix the HOT water in the house supply.
1. Find out if unit was overloaded. If not, remove
belt from the motor and spin the motor pulley.
Does the motor spin free?
2. Spin the tub pulley. Does the tub spin free?
3. Disconnect plug from the motor and measure
resistance of the windings (pin 1 to pin 2, pin 1
to pin 3, pin 2 to pin 3). All readings should be
between 3 and 6 Ohms.
1. Remove belt from the motor and spin the motor
pulley. Does the motor spin free?
2. Spin the tub pulley. Does the tub spin free?
3. Disconnect the plug from the drive motor and
measure resistance between pins 4 & 5 in the
motor.
4. Disconnect plug from the motor and measure
the resistance of the windings (pin 1 to pin 2,
pin 1 to pin 3, pin 2 to pin 3). All readings
should be between 3 and 6 Ohms.
1. Communication problem. Check the wiring
between the main control board and the
motor control board.
1. Communication problem. Check wiring between
the main control board and user interface board.
1. Have power company check the frequency and
voltage of the incoming power.
1. Check the resistance of the heating element. It
should be approximately 14 ohms.
2. Check the resistance between ground and both
heater terminals. It should be open when heater
terminals are disconnected.
1. Check the resistance of the drum water NTC.
Is it around 4.8K ohms?
1. Check wiring between the main control board
and motor control board.
1. Are the hot and cold water hoses switched?
2. Is HOT water about the same temperature as
the cold?
Error Code Test Chart
Test
Check
Correction
Содержание EWFLW65H - 27'' Front-Load Washer
Страница 2: ......
Страница 16: ...B Ba as si ic c I In nf fo or rm ma at ti io on n 1 14 Notes ...
Страница 17: ...Installation Information 2 1 Section 2 Installation Information ...
Страница 23: ...Installation Information 2 7 Installed Washer Dimensions ...
Страница 39: ...Electronic Control 3 1 Section 3 Electronic Control ...
Страница 41: ...Electronic Control 3 3 Wave Touch Washer Cycle Chart ...
Страница 43: ...Electronic Control 3 5 IQ Touch Washer Cycle Chart ...
Страница 63: ...4 1 Component Teardown Section 4 Component Teardown ...
Страница 85: ...Troubleshooting 5 1 Section 5 Troubleshooting ...
Страница 91: ...6 1 Wiring Diagrams Section 6 Wiring Diagrams ...
Страница 92: ...6 2 Wiring Diagrams Model EWFLW65H EIFLW55H ...