PRODUCT MAINTENANCE
NP_AD500-2250-1_01_2020
-42-
01/2020
If the dryer chambers are under pressure, proceed in accordance with Chapter 21.1.
Unscrew the 1 screw from the valve connector.
Disconnect the valve connector (1).
Unscrew the 4 screws (2).
Remove the solenoid valve (3).
Remove the valve seal (4-1) from the valve module body (see 21.15).
Physically clean the valve seat surface to remove any impurities.
Physically clean the 16 screws to remove the thread locking adhesive.
Install the solenoid valve (see Chapter 21.15).
Install the new valve seal (4-1) (see Chapter 21.15).
Install the new solenoid valve using the 4 screws (2) and use a thread locking adhesive on the
threads of the screws (such as Loctite 243).
Reconnect the solenoid valve connector and attach with a screw.
Turn on the dryer.
Switch on the compressor.
Check for any dryer leaks.
Fig. 20: Replacement of solenoid valve