PRODUCT MAINTENANCE
NP_AD500-2250-1_01_2020
-36-
01/2020
21.3. Check of product operation
Check fans operation (visually)
– the fans must be operating when the air supply is operating. In
case of a negative result, look for the cause of the given condition or call service.
Check if the power cord and pneumatic hoses are not damaged. Replace the damaged parts or
call service.
Check ambient temperature
– ambient temperature must be below temperature limit (40°C).
Improve cooling in the room if the temperature is higher.
Check the service indicator on the display screen and schedule service as needed.
Check the operating condition of the equipment (see Chapter 21.6)
21.4. Check of pneumatic connection leakage and device inspection
Leakage check
Check for leaks in the dryer’s pneumatic system when the dryer is running and pressurised.
Use a leak analyser or soapy water to check all joints and connections for leaks. Tighten or reseal
the connections where leaks are found.
Device inspection
Fan operation check
– the fans must be running during the dryer operation.
Check the solenoid valves in the valve module
– the valves should cyclically switch the dryer
chambers as described in Chapter 8.1.
Check the condition of the internal filters and filter sets
– the filters must be undamaged and
sufficiently clean.
Check the operation of the automatic condensate drain.
Check the operating condition of the equipment (see Chapter 21.6).
Replace any defective parts, if needed.
21.5. Check of electrical connection
Risk of electric shock.
Check electrical connections on the device disconnected from the mains.
Check mechanical function of the main switch.
Check if the power cable and conductors are not damaged.
Visually check if cables are connected to the terminal box.
Check all screw connections of the green-yellow PE grounding conductor.
21.6. Checking the operating condition of the equipment
Check the service and failure indicators on the display unit as specified in Chapter 20 and
schedule service or repairs as needed.
Only a service technician is permitted to modify program parameters using the cursor buttons on
the LOGO! module after entering password.
The operator may monitor the individual values on the display but has no access to the
parameters of the program.
Содержание AD2250
Страница 1: ...AD500 2250 User manual N vod na pou itie...
Страница 2: ......
Страница 4: ...CONTENTS 5 OBSAH 46...
Страница 14: ...PRODUCT DESCRIPTION NP_AD500 2250 1_01_2020 14 01 2020 Valve switching diagram ECONOMY mode...
Страница 16: ...PRODUCT DESCRIPTION NP_AD500 2250 1_01_2020 16 01 2020 Fig 2 Dryer AD1500 Fig 3 Dryer AD2250...
Страница 55: ...POPIS V ROBKU 01 2020 55 NP_AD500 2250 1_01_2020 asov diagram prep nania ventilov re im ECONOMY...
Страница 57: ...POPIS V ROBKU 01 2020 57 NP_AD500 2250 1_01_2020 Obr 2 Su i AD1500 Obr 3 Su i AD2250...
Страница 90: ......
Страница 91: ......