GAS CONNECTION
Refit the burner tray into the firebox, fit the two screws through the locating holes in the tray legs,
and tighten.
Purge the gas supply thoroughly to remove air and dirt/debris
BEFORE
connection. Now discon-
nect the inlet restrictor elbow from the inlet pipe. Connect the previously installed gas supply to
inlet restrictor elbow, and re-fit the restrictor elbow to the inlet pipe of the appliance.
If the data/control plate is not already fitted, attach with two screws, ensuring the control knob
is free to be depressed fully.
FUEL BED LAYOUT - Eko 3021 MODELS
This fire is supplied with 11 ceramic coals. The coals
may vary slightly in size, shape, in order to allow a
realistic layout.
Firstly, remove the ceramic components from their pro-
tective packaging, and place the brick panel against the
rear of the firebox
Place the ceramic combustion matrix onto the burner.
Place the front row of five coals on to the matrix. Ensure
the coals are firmly against the side cheeks as shown in
the photograph. If necessary, pull the coals forward
slightly to ensure their rear edges do not overhang the
flame ports. The edges of the coals MUST NOT be
allowed to enter the flame ports.
Place the middle row of four coals onto the supports in
the matrix, over the top of the holes. Ensure the coals
are not turned sideways, such that they actually enter
the holes.
Finally, place the rear row of two coals.
Note: The coals must not be crammed together, or
inserted into the holes in the matrix. A well laid out,
generously spaced coal layout will give the best
results.
The coals may be rotated slightly within their
positions to give a good visual effect. Pay special atten-
tion to finally adjust the coals with the fire lit on the HIGH setting in order to ensure that no flames
play onto the firebox sides. This will reduce the possiblity of heat discolouration.
The fire is designed to operate correctly with the coals supplied when assembled according
to the instructions. Never add to the eleven coals, or change them for a different type. Never
throw rubbish or other matter onto the fuelbed.
13