background image

FUEL BED LAYOUT  -  continued
Eko 3031 MODELS

Pebble Effect Option

3. Take five more ceramic pebbles and position
as shown to form the ‘second row’ of the fuel
effect. The pebbles may be rotated as desired
to fit into the  gaps between the supports in
order to create a random, realistic effect.
Again, remember not to push the pebbles
down too far into the valleys between the sup-
ports as this can have a detrimental effect to
the flame picture.

4. Now take another two pebbles and place
behind the second row of coals, next to each
other in the centre of the fuel bed. The pebbles
may be orientated as desired to achieve a real-
istic effect. Keep the spacing between the peb-
bles even and uniform.  

5. Finally, take the four remaining large peb-
bles and place at the back of the fuel matrix as
shown. 
Once again, the pebbles may be orientated as
desired in order to give a realistic effect. Avoid
pushing the pebbles down between the sup-
ports. The fuel bed layout is now complete.  

The fire is designed to operate correctly
with the pebbles supplied when assembled
according to the instructions. Never add to
the sixteen pebbles, or change them for a
different type. Never throw rubbish or other
matter onto the fuel bed. 

Due to the light

colour of the pebbles, some discolouration/sooting is to be expected during normal use. 

FITTING THE DECORATIVE FRAME AND FRONT

The appliance is supplied with a decorative frame in a variety
of finishes. The frame is held onto the firebox by one of two
methods; either by magnetic pieces fitted to the steel back-
ing plates, or as a three piece clip-on assembly. If not pre-fit-
ted, the clip-on frame pieces should be hooked over the outer
edges of the fireframe, and pushed firmly home. The sides
should be fixed first,  followed by the top bar, which overlaps
the sides. Push firmly home. A plastic protective film may be
applied to the outside of the frame and should be removed
at this stage.

IMPORTANT : Due to the possibility of sharp edges, care
should be taken when handling the three-piece frame
components. The use of protective gloves is recommend-
ed.

Place the decorative firefront in front of the fire and slide the ashpan door into place. The fire-
front shown in these instructions may be different to the one supplied with the appliance.

16

9.2

9.3

©

2009 Focal Point Fires plc.

Содержание eko 3021

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 3021 eko 3031 fan flue fuel effect gas fire...

Страница 2: ...h of at least 300mm depth This appliance is factory set for operation on the gas type and at the pressure stated on the appliance data plate This appliance is available with a number of fuel effect op...

Страница 3: ...iance Data Installation Requirements Terminal Location Site Requirements Ventilation Unpacking the Appliance Component Checklist Preparing for Installation Outer Wall Aperture Gas Supply Routing Insta...

Страница 4: ...ges and car ports then further advice should be sought from CORGI or the manufacurer 2 APPLIANCE DATA Eko 3021 models Eko 3031 models Gas Group G20 Natural Gas CAT I2H G20 Natural Gas CAT I2H Inlet Pr...

Страница 5: ...f protecting this type of roof from heat build up TERMINAL LOCATION Minimum location distances A 300mm above ground level roof or balcony level B 200mm below balconies or car ports C 1500mm vertically...

Страница 6: ...or fixed fender of at least 50mm high The non combustible hearth must extend a minimum of 300mm in front of and 150mm either side of the live part of the appliance The hearth must therefore be a mini...

Страница 7: ...amic fibre combustion matrix 1 Terminal guard cage 1 Front coal piece Eko 3031 models 1 Fan box cover 1 Bag of 11 moulded coals Eko 3021 coal models 1 Fan box trim 1 Bag of 16 moulded ceramic coals Ek...

Страница 8: ...diameter aperture centred around the pilot hole If the fan terminal is to be recessed into the outer leaf the hole should be opened up to the dimensions given in the diagram Clear all the brick rubble...

Страница 9: ...future installation of cavity wall insulation from coming into contact with hot areas of the appliance At this point the false chimney breast or fire surround should be installed Note When constructi...

Страница 10: ...occupants and protect any other parts of the building against dust infiltration Areas that are opened up will need to be protected against rain or snow during the work and if there is a risk of frost...

Страница 11: ...are is taken to prevent combustible materials from contact with hot surfaces The appliance must be installed in accordance with British Gas documents DM2 and DM3 or the Institute of Gas Engineers publ...

Страница 12: ...r wall from the heat effect of the flue It may be advantageous to use a sheet of Superlux board for this purpose Installation by setting the appliance into the inner leaf of wall When setting the appl...

Страница 13: ...feed through the back of the firebox and fit the grommet seal if applicable Now carefully slide the appliance back into position and secure into place using the two previously drilled holes Ensure the...

Страница 14: ...res in the sides of the fan terminal MUST be allowed to vent to the cavity to aid cooling of components within With the terminal fixed into position the wires may now be connected Attach the green ear...

Страница 15: ...ainst the side cheeks as shown in the photograph If necessary pull the coals forward slightly to ensure their rear edges do not overhang the flame ports The edges of the coals MUST NOT be allowed to e...

Страница 16: ...3 Open the bag of 16 moulded coals All of the coals are the same Take five coals and place them as shown Care should be taken to ensure that the coals bridge the gap between the front coal and the fou...

Страница 17: ...sembled according to the instructions Never add to the sixteen coals or change them for a different type Never throw rubbish or other matter onto the coal bed FUELBEDLAYOUT Eko 3031 MODELS Pebble Effe...

Страница 18: ...d according to the instructions Never add to the sixteen pebbles or change them for a different type Never throw rubbish or other matter onto the fuel bed Due to the light colour of the pebbles some d...

Страница 19: ...he control knob in and return to the pilot position and release To turn the fire OFF keep the knob pressed in return to the off position and release Press the OFF button on the control box to switch o...

Страница 20: ...smoke match across the opening All the smoke should be drawn into the upper firebox Any smoke returning into the room indicates that spillage is occurring If the initial test fails run the fire for a...

Страница 21: ...see the relevant sections CLEANING THE CERAMICS Remove the firefront and place to one side Remove the ceramic components Gently clean in the open air Be careful not to create dust from the coals Where...

Страница 22: ...an Press the ON switch the fan should build up speed with the warning light illuminated and then rest at normal operating speed The light on the control box should extinguish The safety solenoid on th...

Страница 23: ...effect of extractor fans Fan runs but pilot flame will not hold Loose thermocouple connection in rear of gas valve when control knob is released Check pilot flame is engulfing tip of thermocouple Pil...

Страница 24: ...firm are concerned Combustible items such as flooring and furniture and soft wall coverings such as flock blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant secti...

Страница 25: ...on the power supply and momentarily press the ON switch on the control box The fan should operate with the warning light illuminated After a very short time the fan will run at nor mal speed and a cl...

Страница 26: ...e may damage the finish To re assemble ensure the magnets are place on the steel backing pieces and re fit to the firebox IMPORTANT Due to the possibility of sharp edges care should be taken when clea...

Отзывы: