FLUE SPILLAGE MONITORING SYSTEM
This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no
apparent reason then several reasons may be suspected. If a door or window has been opened
creating a draught, then pilot disturbance could be the problem, and removal of the draught
should resolve this. The fire can then be re-lit in accordance with the previous section. A sealing
grommet may have been ommited when the fire was installed, and the original installer should
be called to check this, the gas pressure and pipework.
If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the
appliance OFF, call in your installer to check any ventilation and carry out any remedial work
required. DO NOT allow the appliance to be used until the installation is passed as safe.
CLEANING
Before carrying out any of the following operations, ensure that the fire is OFF and completely
cold.
FIREFRAME - This is retained by one of two methods, either by magnetic backing pieces, or a three
piece clip-on assembly. The magnetic frame may be removed for cleaning if required, however the
clip-on style must not be removed. A wipe with a dry cloth is normally sufficient, but on stains it
is permissible to use a damp cloth with a mild household cleaner, followed by a wipe with a dry
cloth. DO NOT use abrasive cleaners as these may damage the finish. To re-assemble ensure the
magnets are place on the steel backing pieces, and re-fit to the firebox.
IMPORTANT : Due to the possibility of sharp edges, care should be taken when cleaning the
three-piece frame components. The use of protective gloves is recommended.
FIREFRONT - Any dust accumulating in the firefront may be removed using a vacuum cleaner or
dry cloth. Heavy stains may be removed by using a damp cloth and mild household detergent.
Brass parts of the firefront may be cleaned using a suitable brass cleaner. Replace the front cen-
trally against the fire after cleaning.
PAINTED AREAS - These can be cleaned using a dry cloth.
COALS AND CERAMICS - See the relevant section in the Installation Guide of these instructions. Do
not create dust from the coals. Clean gently in the open air. Replace components with original
spares only as necessary.
LIST OF SPARES
PART NO.
ITEM
F780059
Pack of 11 coals (Eko 3021 models)
F780034
Fuel matrix (Eko 3021 models)
F550038
Pack of 16 coals (Eko 3031 models)
F550050
Pack of 16 ceramic pebbles (Eko 3031 models)
F780007
Fuel Matrix (Eko 3031 coal version)
F780016
Fuel Matrix (Eko 3031 pebble version)
F780008
Front ceramic strip (Eko 3031 coal version)
F780017
Front ceramic strip (Eko 3031 pebble version)
F730006
Pilot unit
Please Enquire
Decorative Frame
Please Enquire
Decorative Front
3
6.0
7.0
8.0
As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend
details and/or specifications without prior notice.
F860626
©
2009 Focal Point Fires plc.