FLUE SPILLAGE MONITORING SYSTEM

This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no
apparent reason then several reasons may be suspected. If a door or window has been opened
creating a draught, then pilot disturbance could be the problem, and removal of the draught
should resolve this. The fire can then be re-lit in accordance with the previous section. A sealing
grommet may have been ommited when the fire was installed, and the original installer should
be called to check this, the gas pressure and pipework.

If pilot disturbance is not the cause, then the ODS safety system may be in operation. Switch the
appliance OFF, call in your installer to check any ventilation and carry out any remedial work
required. DO NOT allow the appliance to be used until the installation is passed as safe.

CLEANING

Before carrying out any of the following operations, ensure that the fire is OFF and completely
cold.

FIREFRAME - This is retained by one of two methods, either by magnetic backing pieces, or a three
piece clip-on assembly. The magnetic frame may be removed for cleaning if required, however the
clip-on style must not be removed. A wipe with a dry cloth is normally sufficient, but on stains it
is permissible to use a damp cloth with a mild household cleaner, followed by a wipe with a dry
cloth. DO NOT use abrasive cleaners as these may damage the finish. To re-assemble ensure the
magnets are place on the steel backing pieces, and re-fit to the firebox.

IMPORTANT : Due to the possibility of sharp edges, care should be taken when cleaning the
three-piece frame components. The use of protective gloves is recommended.

FIREFRONT - Any dust accumulating in the firefront may be removed using a vacuum cleaner or
dry cloth. Heavy stains may be removed by using a damp cloth and mild household detergent.
Brass parts of the firefront may be cleaned using a suitable brass cleaner. Replace the front cen-
trally against the fire after cleaning.

PAINTED AREAS - These can be cleaned using a dry cloth.

COALS AND CERAMICS - See the relevant section in the Installation Guide of these instructions. Do
not create dust from the coals. Clean gently in the open air. Replace components with original
spares only as necessary.

LIST OF SPARES

PART NO.

ITEM

F780059

Pack of 11 coals (Eko 3021 models)

F780034

Fuel matrix (Eko 3021 models)

F550038

Pack of 16 coals (Eko 3031 models)

F550050

Pack of 16 ceramic pebbles (Eko 3031 models)

F780007

Fuel Matrix (Eko 3031 coal version)

F780016

Fuel Matrix (Eko 3031 pebble version)

F780008

Front ceramic strip (Eko 3031 coal version)

F780017

Front ceramic strip (Eko 3031 pebble version)

F730006

Pilot unit

Please Enquire

Decorative Frame

Please Enquire

Decorative Front

3

6.0

7.0

8.0

As our policy is one of continuous improvement and development , we hope therefore you will understand we must retain the right to amend
details and/or specifications without prior notice.

F860626

©

2009 Focal Point Fires plc.

Содержание eko 3021

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 3021 eko 3031 fan flue fuel effect gas fire...

Страница 2: ...h of at least 300mm depth This appliance is factory set for operation on the gas type and at the pressure stated on the appliance data plate This appliance is available with a number of fuel effect op...

Страница 3: ...iance Data Installation Requirements Terminal Location Site Requirements Ventilation Unpacking the Appliance Component Checklist Preparing for Installation Outer Wall Aperture Gas Supply Routing Insta...

Страница 4: ...ges and car ports then further advice should be sought from CORGI or the manufacurer 2 APPLIANCE DATA Eko 3021 models Eko 3031 models Gas Group G20 Natural Gas CAT I2H G20 Natural Gas CAT I2H Inlet Pr...

Страница 5: ...f protecting this type of roof from heat build up TERMINAL LOCATION Minimum location distances A 300mm above ground level roof or balcony level B 200mm below balconies or car ports C 1500mm vertically...

Страница 6: ...or fixed fender of at least 50mm high The non combustible hearth must extend a minimum of 300mm in front of and 150mm either side of the live part of the appliance The hearth must therefore be a mini...

Страница 7: ...amic fibre combustion matrix 1 Terminal guard cage 1 Front coal piece Eko 3031 models 1 Fan box cover 1 Bag of 11 moulded coals Eko 3021 coal models 1 Fan box trim 1 Bag of 16 moulded ceramic coals Ek...

Страница 8: ...diameter aperture centred around the pilot hole If the fan terminal is to be recessed into the outer leaf the hole should be opened up to the dimensions given in the diagram Clear all the brick rubble...

Страница 9: ...future installation of cavity wall insulation from coming into contact with hot areas of the appliance At this point the false chimney breast or fire surround should be installed Note When constructi...

Страница 10: ...occupants and protect any other parts of the building against dust infiltration Areas that are opened up will need to be protected against rain or snow during the work and if there is a risk of frost...

Страница 11: ...are is taken to prevent combustible materials from contact with hot surfaces The appliance must be installed in accordance with British Gas documents DM2 and DM3 or the Institute of Gas Engineers publ...

Страница 12: ...r wall from the heat effect of the flue It may be advantageous to use a sheet of Superlux board for this purpose Installation by setting the appliance into the inner leaf of wall When setting the appl...

Страница 13: ...feed through the back of the firebox and fit the grommet seal if applicable Now carefully slide the appliance back into position and secure into place using the two previously drilled holes Ensure the...

Страница 14: ...res in the sides of the fan terminal MUST be allowed to vent to the cavity to aid cooling of components within With the terminal fixed into position the wires may now be connected Attach the green ear...

Страница 15: ...ainst the side cheeks as shown in the photograph If necessary pull the coals forward slightly to ensure their rear edges do not overhang the flame ports The edges of the coals MUST NOT be allowed to e...

Страница 16: ...3 Open the bag of 16 moulded coals All of the coals are the same Take five coals and place them as shown Care should be taken to ensure that the coals bridge the gap between the front coal and the fou...

Страница 17: ...sembled according to the instructions Never add to the sixteen coals or change them for a different type Never throw rubbish or other matter onto the coal bed FUELBEDLAYOUT Eko 3031 MODELS Pebble Effe...

Страница 18: ...d according to the instructions Never add to the sixteen pebbles or change them for a different type Never throw rubbish or other matter onto the fuel bed Due to the light colour of the pebbles some d...

Страница 19: ...he control knob in and return to the pilot position and release To turn the fire OFF keep the knob pressed in return to the off position and release Press the OFF button on the control box to switch o...

Страница 20: ...smoke match across the opening All the smoke should be drawn into the upper firebox Any smoke returning into the room indicates that spillage is occurring If the initial test fails run the fire for a...

Страница 21: ...see the relevant sections CLEANING THE CERAMICS Remove the firefront and place to one side Remove the ceramic components Gently clean in the open air Be careful not to create dust from the coals Where...

Страница 22: ...an Press the ON switch the fan should build up speed with the warning light illuminated and then rest at normal operating speed The light on the control box should extinguish The safety solenoid on th...

Страница 23: ...effect of extractor fans Fan runs but pilot flame will not hold Loose thermocouple connection in rear of gas valve when control knob is released Check pilot flame is engulfing tip of thermocouple Pil...

Страница 24: ...firm are concerned Combustible items such as flooring and furniture and soft wall coverings such as flock blown vinyl or embossed paper may discolour if fitted too close to the fire See relevant secti...

Страница 25: ...on the power supply and momentarily press the ON switch on the control box The fan should operate with the warning light illuminated After a very short time the fan will run at nor mal speed and a cl...

Страница 26: ...e may damage the finish To re assemble ensure the magnets are place on the steel backing pieces and re fit to the firebox IMPORTANT Due to the possibility of sharp edges care should be taken when clea...

Отзывы: