FIREFRONT
This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate
airflow under the firebed for the correct functioning of this appliance.
Compliance with safety standards cannot be guaranteed if another style of front is used.
CLEARANCES TO COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the
dimensions given below.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the
frame of the appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock,
blown vinyl and embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No purpose provided ventilation is normally required for this appliance
.
The requirements of
other appliances operating in the same space or room, and the results of a spillage test must be
taken into consideration when assessing ventilation requirements, this will have been carried out
by your CORGI registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules
in force.
OPERATING INSTRUCTIONS
Turn on the power supply and momentarily press the ON switch on the control box. The fan
should operate with the warning light illuminated. After a very short time the fan will run at nor-
mal speed and a click may be heard as the safety solenoid opens. The warning light should extin-
guish.
The pilot is visible through the underside of the left hand front
coal strip. Push in and turn the control knob to the SPARK posi-
tion, and hold there for a few seconds. Continue turning anti-
clockwise through the spark click to the PILOT light position,
ensuring the pilot has lit. If not, return the knob clockwise, and
repeat.
When the pilot lights after the spark, keep the knob depressed
for approximately ten seconds. Now release the knob and the
pilot should stay alight. If not, repeat ignition. If the pilot is
extinguished
during use
, wait three minutes before repeating
the ignition procedure. To achieve the HIGH setting, push the control knob in slightly and con-
tinue turning anti-clockwise to the high position. The main burner should light after a few sec-
onds. To decrease the setting to LOW, turn the control knob clockwise to the low setting. To turn
to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to
the pilot position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release. Press the
OFF button on the control box to switch off the fan.
2
2.0
3.0
4.0
5.0
Maximum depth of shelf Minimum distance from finished hearth
surface to underside of shelf
100mm (4in)
745mm (29 1/4 in)
150mm (6in)
845mm (33 1/4 in)
203mm (8in)
895mm (35 1/4 in)
©