FIREFRONT
This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate
airflow under the fuelbed for the correct functioning of this appliance.
Compliance with safety standards cannot be guaranteed if another style of front is used.
CLEARANCES TO COMBUSTIBLES
A combustible shelf may be fixed to the wall above the fire, providing that it complies with the
dimensions given below.
A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the
frame of the appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock,
blown vinyl and embossed paper) positioned too close to the appliance may discolour or scorch.
VENTILATION
No purpose provided ventilation is normally required for this appliance.
The requirements of
other appliances operating in the same space or room, and the results of a spillage test must be
taken into consideration when assessing ventilation requirements, this will have been carried out
by your CORGI registered installer.
For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules
in force.
FUEL BED LAYOUT
(coal effect models)
1. Remove the combustion matrix from its protec-
tive packaging, and position onto the burner tray
as shown. The front edge of the matrix should sit
snugly behind the back edge of the burner rails. Do
not fit the matrix on top of the burner rails.
2. Next, remove the front coal strip from its pro-
tective packaging and position as shown. The rear
edge of the front coal strip should fit in front of the
burner rail. Again, do not to place on top of the
burner rails. When the front coal is in position bend
up the three metal tags at the front of the tray to
retain (inset).
2
Maximum depth of shelf Minimum distance from inside edge of
fire frame to underside of shelf
100mm (4in)
203mm (8in)
150mm (6in)
305mm (12in)
203mm (8in)
356mm (14in)
2.0
3.0
4.0
5.0
Correct
Incorrect
©
2009 Focal Point Fires plc.