This fire is supplied with a particular style of firefront. Use of the firefront will ensure an adequate
airflow under the fuelbed for the correct functioning of this appliance.

Compliance with safety standards cannot be guaranteed if another style of front is used.

CLEARANCES TO COMBUSTIBLES

A combustible shelf may be fixed to the wall above the fire, providing that it complies with the
dimensions given below.

A non-combustible shelf may be fitted to within 10mm of the top edge of the fireframe.
Combustible materials, such as wood, may be fitted to within 100mm (4in) of either side of the
frame of the   appliance, providing the forward projection does not exceed 100mm (4in).
Any combustible side walls must be at least 500mm to the side of the radiant heat source.
As with all heating appliances, any decorations, soft furnishings, and wall coverings (i.e. flock,
blown vinyl and embossed paper) positioned too close to the appliance may discolour or scorch.

VENTILATION

No purpose provided ventilation is normally required for this appliance.

The requirements of

other appliances operating in the same space or room, and the results of a spillage test must be
taken into consideration when assessing ventilation requirements, this will have been carried out
by your CORGI registered installer.

For Republic of Ireland, ventilation may be required, see IS 813, ICP3, IS 327, and any other rules
in force.

FUEL BED LAYOUT 
(coal effect models)

1. Remove the combustion matrix from its protec-
tive packaging, and position onto the burner tray
as shown. The front edge of the matrix should sit
snugly behind the back edge of the burner rails. Do
not fit the matrix on top of the burner rails.

2. Next, remove the front coal strip  from its pro-
tective packaging and position as shown. The rear
edge of the front coal strip should fit in front of the
burner rail. Again, do not to place on top of the
burner rails. When the front coal is in position bend
up the three metal tags at the front of the tray to
retain (inset).

2

Maximum depth of shelf                Minimum distance from inside edge of

fire frame to underside of shelf

100mm (4in)

203mm (8in)

150mm (6in)

305mm (12in)

203mm (8in)

356mm (14in)

2.0

3.0

4.0

5.0

Correct

Incorrect

©

2009 Focal Point Fires plc.

Содержание eko 2050

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 2050 fuel effect gas fire...

Страница 2: ...tible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and at the pressure stated on the appliance data plate This appliance is a manual control version with...

Страница 3: ...Gas Safety Installation and Use Regulations 1998 the relevant British Standards for Installation Codes of Practice and in accordance with the Manufacturers Instructions The installation shall also be...

Страница 4: ...flue must be connected to only one fireplace and the flue must not vent more than one appli ance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the...

Страница 5: ...75mm 7in minimum diameter twin wall flue conforming to BS 715 Any existing under grate draught device must be sealed off The opening wall must be non combustible The appliance requires a hearth with n...

Страница 6: ...in these circumstances may be the best solu tion Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2 Ventilation locat ed underneath or within the immediate vicinity of the fire...

Страница 7: ...fire box to prevent the ingress of dirt and dust Using 8mm diameter pipe connect the appliance to the gas supply point The appliance must be fitted with rigid or semi rigid pipe of 8mm external diamet...

Страница 8: ...tion The main burner will light and be controlled in accordance with the main burner control knob set ting Adjust the main burner control knob to the desired setting If the pilot is extinguished durin...

Страница 9: ...this If a grommet seal has been left out of the firebox if fitted then this also will also cause inter mittent shutdown The gas pressure reaching the fire must also be checked The thermocouple connec...

Страница 10: ...the coals or ceramics or wash them in water SERVICING Ensure that the fire is fully cold before attempting service A suggested procedure for servicing is detailed below 1 Lay out the dust sheet and t...

Страница 11: ...are evident then a genuine spare must be used If a large amount of debris is present in the fil ter then the pipework and control should be thoroughly cleaned before re assembly TROUBLESHOOTING GUIDE...

Страница 12: ...tion for further details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the fuel effect must be of the...

Страница 13: ...ormally required for this appliance The requirements of other appliances operating in the same space or room and the results of a spillage test must be taken into consideration when assessing ventilat...

Страница 14: ...behind the second row of coals in order to complete the third row The coals may be orientated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals...

Страница 15: ...of the fuel bed The pebbles may be orien tated as desired to achieve a realistic effect Keep the spacing between the pebbles even and uni form 5 Finally take the four remaining pebbles and place at t...

Страница 16: ...aining two medium sized logs numbered 5 and 7 and place in a horizontal position shown 5 first resting on the front log strip 7 next resting on 5 Now take the smallest log numbered 12 and position in...

Страница 17: ...ner will light and be controlled in accordance with the main burner control knob set ting Adjust the main burner control knob to the desired setting If the pilot is extinguished during use of the fire...

Страница 18: ...ion in the installation guide of these instructions Do not create dust from the coals Clean gently in the open air Replace components with original spares only as necessary SERVICING The fire and flue...

Отзывы: