background image

FUEL BED LAYOUT 
(Log effect option) continued

2. Open the bag of 9 moulded ceramic logs. All of
the logs except two are the same. Take the largest
log (numbered 16) and place it as shown. Care
should be taken to ensure that the orientation is
correct and the log fits snugly into its position.

3. Take the two medium sized logs (numbered 15
and  8) position the log numbered 8 on the left
hand side ensuring correct orientation. Place the
log numbered 15 on the right hand side again
ensuring correct orientation. Both these logs will fit
securely into their allocated poisition, they may
require rotating slightly to ensure this.

4. Now take the remaining large log (numbered 4)
and position vertically as shown, ensuring correct
orientation. The base of this log must rest secure-
ly on the front log strip. Take one of the smaller
logs (numbered 14) and position in between the
two vertically positioned logs ennsuring the orien-
tation is correct. Keep the spacing between these
logs uniform.

5. Finally, take the remaining two medium sized
logs (numbered 5 and 7) and place in a horizontal
position shown,  5 first, resting on the front log
strip. 7 next resting on 5. Now take the smallest
log (numbered 12) and position in the orientation
shown ensuring the log does not fall into the
matrix but rests securely on the allocated sup-
ports. Now take the final log (numbered 14) and
place in a horizontal position as shown. Ensure
there is even spacing between the logs and rotate
if necessary to provide a stable fit onto the matrix.
The fuel bed layout is now complete.

The fire is designed to operate correctly with
the logs supplied when assembled according to
the instructions. Never add to the nine logs, or
change them for a different type. Never throw
rubbish or other matter onto the fuel bed.

OPERATING INSTRUCTIONS 
(manual control models)

The pilot is visible through the left hand side of the front ceram-
ic strip. Push in and turn the control knob to the SPARK position,
and hold there for a few seconds.

Continue turning anti-clockwise through the spark click to the
PILOT light position, ensuring the pilot has lit. If not, return the
knob clockwise, and repeat.

5.2

6.0

5

16

15

8

4

14

5

14

12

©

2009 Focal Point Fires plc.

Содержание eko 2050

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 2050 fuel effect gas fire...

Страница 2: ...tible hearth of at least 300mm depth This appliance is factory set for operation on the gas type and at the pressure stated on the appliance data plate This appliance is a manual control version with...

Страница 3: ...Gas Safety Installation and Use Regulations 1998 the relevant British Standards for Installation Codes of Practice and in accordance with the Manufacturers Instructions The installation shall also be...

Страница 4: ...flue must be connected to only one fireplace and the flue must not vent more than one appli ance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the...

Страница 5: ...75mm 7in minimum diameter twin wall flue conforming to BS 715 Any existing under grate draught device must be sealed off The opening wall must be non combustible The appliance requires a hearth with n...

Страница 6: ...in these circumstances may be the best solu tion Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2 Ventilation locat ed underneath or within the immediate vicinity of the fire...

Страница 7: ...fire box to prevent the ingress of dirt and dust Using 8mm diameter pipe connect the appliance to the gas supply point The appliance must be fitted with rigid or semi rigid pipe of 8mm external diamet...

Страница 8: ...tion The main burner will light and be controlled in accordance with the main burner control knob set ting Adjust the main burner control knob to the desired setting If the pilot is extinguished durin...

Страница 9: ...this If a grommet seal has been left out of the firebox if fitted then this also will also cause inter mittent shutdown The gas pressure reaching the fire must also be checked The thermocouple connec...

Страница 10: ...the coals or ceramics or wash them in water SERVICING Ensure that the fire is fully cold before attempting service A suggested procedure for servicing is detailed below 1 Lay out the dust sheet and t...

Страница 11: ...are evident then a genuine spare must be used If a large amount of debris is present in the fil ter then the pipework and control should be thoroughly cleaned before re assembly TROUBLESHOOTING GUIDE...

Страница 12: ...tion for further details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the fuel effect must be of the...

Страница 13: ...ormally required for this appliance The requirements of other appliances operating in the same space or room and the results of a spillage test must be taken into consideration when assessing ventilat...

Страница 14: ...behind the second row of coals in order to complete the third row The coals may be orientated as desired to achieve a realistic effect Keep the spacing between the coals even and uniform The two coals...

Страница 15: ...of the fuel bed The pebbles may be orien tated as desired to achieve a realistic effect Keep the spacing between the pebbles even and uni form 5 Finally take the four remaining pebbles and place at t...

Страница 16: ...aining two medium sized logs numbered 5 and 7 and place in a horizontal position shown 5 first resting on the front log strip 7 next resting on 5 Now take the smallest log numbered 12 and position in...

Страница 17: ...ner will light and be controlled in accordance with the main burner control knob set ting Adjust the main burner control knob to the desired setting If the pilot is extinguished during use of the fire...

Страница 18: ...ion in the installation guide of these instructions Do not create dust from the coals Clean gently in the open air Replace components with original spares only as necessary SERVICING The fire and flue...