OPERATING INSTRUCTIONS (manual control models) - continued
When the pilot lights after the spark, keep the knob depressed for approximately ten seconds.
Now release the knob and the pilot should stay alight. If not, repeat ignition. If the pilot is extin-
guished
during use
, wait three minutes before repeating the ignition procedure.
To achieve the HIGH setting, push the control knob in slightly and continue turning anti-clockwise
to the high position. The main burner should light after a few seconds.
To decrease the setting to LOW, turn the control knob clockwise to the low setting.
To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and
return to the pilot position and release.
To turn the fire OFF, keep the knob pressed in, return to the off position and release.
OPERATING THE FIRE
(remote control models)
The pilot is visible through the left hand side of the
front ceramic strip. Turn the main burner control
(shown on left hand side of control valve) knob fully
anti-clockwise.
Turn ignition knob (shown on right hand side of control
valve) slightly left towards the ignition position until
reaching the stop, press down and hold for 5 seconds
(only pilot gas is flowing).
Continue pressing down the knob while turning further to the left to
activate the piezo spark, continue to hold the knob down for a further
10 seconds after the pilot has been lit. If the pilot does not light repeat
the previous steps.
Upon lighting and after the further 10 seconds, release the knob and
turn further to the left to the ON position. The main burner will light
and be controlled in accordance with the main burner control knob set-
ting. Adjust the main burner control knob to the desired setting.
If the pilot is extinguished during use of the fire, you MUST wait ten
minutes before repeating the ignition procedure.
To turn the main burner OFF whilst keeping the pilot flame lit, turn the
ignition control knob to the pilot position then only the pilot will
remain lit.
To shut the fire off completely, press the ignition control knob down and continue turning to the
right from the pilot position to the OFF position.
A safety interlock prevents re-ignition of the pilot flame until the thermocouple has cooled suffi-
ciently to allow the magnetic valve unit to reset itself.
The remote control unit allows operation of the main burner setting between maximum and pilot
only setting. It does not permanently turn the pilot on or off.
The remote control handset incorporates an inbuilt safety feature to prevent the main burner
being activated or turned up accidentally. It is necessary to press button 1 and 2 (see illustration)
simultaneously to turn the fire up.
To turn the fire down press button 3 only
FLUE SPILLAGE MONITORING SYSTEM
This fire is fitted with a flue spillage safety device (ODS). If the fire shuts down during use for no
apparent reason then several reasons may be suspected. If a door or window has been opened
creating a draught, then pilot disturbance could be the problem, and removal of the draught
should resolve this. The fire can then be re-lit in accordance with the previous section. A sealing
grommet may have been ommited when the fire was installed, and the original installer should
be called to check this, the gas pressure and pipework.
6.0
1
2
3
6
6.1
7.0
©
2009 Focal Point Fires plc.