INSTALLATION REQUIREMENTS
This appliance MUST NOT be installed into a room containing a bath or shower, or where steam
may be present. The fire has been designed to fit into a builders’ opening or fireplace conform-
ing to BS 1251 (and meeting certain dimensional requirements), or a suitable flue box complying
with the constructional requirements of BS 715. Either a ‘Replacement Chairbrick’ or a BS 1251
chairbrick should also be fitted into the builders’ opening. The flue box must be installed onto a
suitable non-combustible insulating surface at least 12mm thick, covering the entire base are of
the box.
The flue must have an effective height of at least three meters, as measured from the hearth to
the top of the flue. Any flue damper plates or restrictors should be removed and no other restric-
tion fitted to the flue. Where removal is not practical, the restriction must be fixed in the fully
open position.
A natural draught flue system is required, and if previously used for solid fuel or oil burning, the
flue and chimney must be swept prior to appliance installation. The flue must be checked before
installation by using a smoke pellet or similar to ensure proper draw and that leakage is not evi-
dent at any joints. Repair and re-test as necessary before the appliance is installed.
The flue must be connected to only one fireplace, and the flue must not vent more than one appli-
ance (i.e. not shared with a gas back boiler). There must be no opening in the flue apart from the
one that the appliance is installed into, and the one venting the gases into the air. A suitable ter-
minal may be fitted, such as class GC1, as regulations allow.
This appliance has been tested for use with circular flues of a minimum internal diameter of
175mm.
The flue termination (cowl) must be of a type suitable for use with an inset Decorative Fuel Effect
Fire BS5871 part 3 contains further details.
2
2.0
3.0
APPLIANCE DATA
Manual control models Remote control models
Gas Group
G20 Natural Gas CAT I2H
G20 Natural Gas CAT I2H
Inlet Pressure
20 mbar (+/- 2.0mbar)
20 mbar (+/- 2.0mbar)
Max Energy Input (gross)
6.8 kW
6.8 kW
Min Energy Input (gross)
3.5 kW
3.5 kW
Pilot Energy Input (gross)
166 W
166 W
Setting Pressure (cold)
15.8 mbar (+/- 1.5mbar)
15.8 mbar (+/- 1.5mbar)
Main Injector Burner
Stereo size 81/Bray cat. 82/420
Stereo size 81/Bray cat. 82/420
Gas Inlet Connection
8mm Inlet Restrictor Elbow
8mm Inlet Restrictor Elbow
Gas Control Valve
Dungs BM 733/NGC 6801
Mertik Maxitrol GV30 series
Ignition
Integral Piezo spark
Integral Piezo spark
Spark Gap
3.5 to 4.5mm
3.5 to 4.5mm
Weight
20 Kg
20 Kg
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appli-
ance Data Badge, and is for decorative purposes.
©
2009 Focal Point Fires plc.