background image

5132685/02

© 

Baxi Heating U.K. Limited 2010.

Model 756

INSET LIVE FUEL EFFECT GAS FIRE

Fitted with one of the following fascia.

Denver, Exquisite,
Madison

or 

Splendour.

(GC No. 32-811-46)

INSTALLER: Please leave this guide with the owner

We trust that this guide gives
sufficient details to enable this
appliance to be installed and
maintained satisfactorily. However, if
further information is required, our

Valor Fires Technical Helpline

will

be pleased to help.
Telephone 

0844 8711 565 

(National

call rates apply in the United
Kingdom).
In the Republic of Ireland
Telephone

0044 844 8711 565.

INSTALLER AND OWNER GUIDE

Summary of Contents for 756

Page 1: ...his guide with the owner We trust that this guide gives sufficient details to enable this appliance to be installed and maintained satisfactorily However if further information is required our Valor F...

Page 2: ...owing address The Company Secretary Baxi Heating UK Limited The Wyvern Business Park Stanier Way Derby DE21 6BF Warning Any person who does any unauthorised act in relation to a copyright work may be...

Page 3: ...e British Standards Institute The Highest Standards Valor Fires is a member of SBGI and HHIC Heating and Hot water Industry Council that work to ensure high standards of safety quality and performance...

Page 4: ...Page 4 INSTALLER GUIDE Baxi Heating U K Limited 2010 INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 36 TO 47...

Page 5: ...9 Fireplace clearances 12 4 10 Installation options 14 4 10 1 Conventional fireplace and hearth 14 4 10 1 1 Hole in the wall Installations 15 4 10 2 Metal flue box and hearth 15 4 10 3 Precast concre...

Page 6: ...or spillage 29 13 3 Flame supervision and spillage monitoring system 30 14 FINAL REVIEW 30 15 SERVICING PARTS REPLACEMENT 31 15 1 To remove the fascia 32 15 2 To remove the burner unit 32 15 3 To remo...

Page 7: ...Fibres RCF which are man made vitreous silicate fibres Excessive exposure to these materials may cause irritation to eyes skin and respiratory tract Consequently it is important not to touch or distur...

Page 8: ...has been measured as specified in BS 7977 1 and the result is as below Model Efficiency Gross 756 47 756 when converted to LPG 47 Page 8 Baxi Heating U K Limited 2010 Gas Natural G20 Propane G31 Inlet...

Page 9: ...GI require their members to work to recognised standards In the United Kingdom the installation must also be in accordance with All the relevant parts of local regulations All relevant codes of practi...

Page 10: ...eason the consumer should be informed to stop using the appliance until the installation and appliance have been thoroughly checked The A S D will shut the appliance down if an unacceptable amount of...

Page 11: ...by the convection box top and side flange seals to ensure good sealing These faces should be made good if necessary 4 7 4 If the appliance is to be fitted against a wall with combustible cladding the...

Page 12: ...excessive unevenness uneven tiles Cotswold stone etc should be rectified The appliance must not stand on combustible materials or carpets 4 9 Fireplace clearances 4 9 1 The minimum height from the ba...

Page 13: ...Page 13 Baxi Heating U K Limited 2010 INSTALLER GUIDE Figure 3 Appliance dimensions and clearances...

Page 14: ...round and hearth as shown in figure 4 and complying with BS1251 after removal of the fireback and sufficient material behind the fireback for a debris catchment space The required fireplace hearth deb...

Page 15: ...ed then a 672mm long fender kerb horizontal bar or other barrier being fixed not less than 50mm above floor level and positioned 300mm in front of the fixing plane of the fire will meet the requiremen...

Page 16: ...as with many appliances sharp bends or horizontal runs in metal flues at the top of the system can be a cause of problems in these types of installation 225mm x 225mm conventional brick flue 175mm dia...

Page 17: ...etary terminals must comply with BS 715 or BS 1289 Any terminal or termination must be positioned in accordance with BS 5440 Part 1 to ensure that the products of combustion can be safely dispersed in...

Page 18: ...of floor sealing tape 4 Eyebolts Carefully remove all the contents Check that all the listed parts are present and in good condition The pack may contain additional components to that stated above Th...

Page 19: ...light a 13 gram smoke pellet and check that there is a definite flow through the flue Verify outside that the smoke exits from one terminal only and that the termination is suitable Observe where pos...

Page 20: ...e hotbox must be kept away from the area which will be taken by the hotbox when it is installed Note that the centre of the appliance inlet T connector is 25mm above the fireplace floor The inlet T co...

Page 21: ...ve the label and retaining screws from the rear sides of the hotbox Position the fireback spacers as shown in figure 12 Secure the fireback spacers using the screws removed previously and the two supp...

Page 22: ...n figure 15 11 The sides have a stepped top face These must be located on the inside the top piece See point 1 of figure 16 The tabs on the top piece must locate on the inside of the side pieces See p...

Page 23: ...ange See figure 17 13 Locate the spacer frame to the rear of the hotbox The foam seal must be to the rear of the spacer frame and NOT against the flanges of the hotbox Secure the spacer frame to the h...

Page 24: ...lied with this appliance Never use plastic plugs instead of the fibre plugs supplied Screw the eyebolts into the plugs Make sure that the bolts are secure 4 Place the hotbox unit close to the fireplac...

Page 25: ...le retainer over the bottom end of each cable 11 Pull each cable taut Push the cable retainers hard up against the back panel The end of the cable adjuster will pass into the hole Tighten the screws i...

Page 26: ...nd secure using the two screws removed previously 2 Supplied with the fire is an elliptical burner bezel Place this within the edge of the burner so that it covers the screws that secure the burner to...

Page 27: ...ally turn the control knob anti clockwise to HIGH Depress the knob slightly to get past the PILOT IGN position The main burner should now light Depress the control knob slightly to release from the HI...

Page 28: ...knob Lower the fascia unit making sure that the retaining hooks locate fully into the brackets on the hotbox See figure 26 12 2 Fitting the heat baffle Supplied with the fire is a heat baffle This baf...

Page 29: ...rther ten minutes and then repeat the test If the smoke is still not drawn into the appliance inspect the sealing to the fireplace surround If the sealing is satisfactory but the appliance is installe...

Page 30: ...he appliance has a flame failure spillage monitoring system Point out the explanation of this system shown in the owner guide under Operating the fire Advise that if the fire goes out for any reason w...

Page 31: ...inimum To ensure that the release of fibres from these RCF articles is kept to a minimum during installation and servicing we recommend that you use a HEPA filtered vacuum to remove any dust and soot...

Page 32: ...onnector 2 Support the inlet T connector to avoid straining the pipework and disconnect the appliance from the inlet T connector 3 Lift and remove the elliptical edge cover from the burner surface 4 R...

Page 33: ...pilot unit 1 Remove the burner unit See section 15 2 2 If turning the burner upside down ensure that the work surface is suitably protected This will avoid damage to the work surface Detach the pilot...

Page 34: ...Replace in the reverse order 15 8 To grease the control tap 1 Detach the gas valve and remove the piezo generator as section 15 7 making sure that the gas valve is in the OFF position 2 Remove the two...

Page 35: ...ng screws 6 Place the burner face down and remove the two burner securing screws from the underside of the burner tray 7 Gently lift the burner tray upward Be careful not to damage the pilot hood 8 Re...

Page 36: ...Page 36 Baxi Heating U K Limited 2010 OWNER GUIDE OWNER GUIDE FOR WARRANTY AND SERVICE INFORMATION SEE PAGES 44 TO 47...

Page 37: ...Burner top surface 42 MAINTENANCE 43 WARRANTY AND SERVICE 44 This gas fire is designed to meet the most stringent quality performance and safety requirements to provide you with many years trouble fr...

Page 38: ...he shelf is not more than 150mm deep For a shelf deeper than 150mm add 12 5mm to the clearance for every 25mm of additional shelf depth See figure1 Do wait three minutes before attempting to relight i...

Page 39: ...at complies with BS 8423 for the protection of young children the elderly and the infirm Such a guard is also recommended for the protection of pet animals Don t hang clothing towels or any other fabr...

Page 40: ...tically shut off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device...

Page 41: ...main burner at its low setting There may be a delay of up to four seconds between the pilot lighting and ignition of the gas at the main burner This is normal and is due to the time required to fill...

Page 42: ...o cool completely The fire will retain heat for some time before cleaning can begin If any pieces of debris are found in the hotbox have the chimney inspected before further use Metal and painted part...

Page 43: ...earance of dangerous exhaust fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at leas...

Page 44: ...promise to you If you experience a fault with your new fire we aim to provide a safe and high quality repair service supported by our dedicated national network of highly skilled engineers If your ins...

Page 45: ...lacement of the complete unit providing the failure is related to a manufacturing fault that cannot be repaired or is uneconomic to repair What this warranty does not cover Repairs to fires which have...

Page 46: ...axi Heating U K Limited 2010 OWNER GUIDE Installer Details Block Capitals Installer Name Gas Safe Register or Corgi Registration Number Company Name Company Address Company Telephone number Company Fa...

Page 47: ...Can be found close to the information label Block Capitals Model 7 5 6 Serial number Can be found on the information label See figure 6 OWNER GUIDE Figure 6 Fascia name Block Capitals A LABEL CONTAINI...

Page 48: ...Baxi Heating U K Limited 2010...

Reviews: