4.
Connect the monitor to a power supply.
There are two options for connecting the monitor to a power supply. Carry out the connection
according to the installation environment and conditions of use.
•
Using the DC power terminal block
• Using the AC power connector
Attention
• Do not supply the monitor with power until it has been properly connected to a power source.
Note
• When both of the power supplies are connected, AC power is prioritized.
●
Using the DC power terminal block
Attention
• It is strongly recommended to separate the FG and terminal (GND) and connect the FG.
Disconnect the terminal block.
Terminal block
3. Connect the electrical wires to the terminal block.
Attention
•
Use electrical wire of AWG 18 to 12 (0.8 mm
2
to 3 mm
2
).
1.
Strip the insulation from the electrical wires (stripping length: 7±0.5 mm).
Add a ferrule to the end of each wire, if required.
Use ferrules manufactured by PHOENIX CONTACT.
Ferrule
7 ± 0.5 mm
2.
Insert the electrical wire into the terminal block. Secure it by tightening the clamp screw
from the bottom using a flat-head screwdriver with a tip width of 2.5 mm.
The input polarities of the terminal block are shown below.
4 3 2 1
Pin No.
Input Polarity
1
DC +24 V
2
DC +24 V
3
GND
4
GND
Flat-head screwdriver
Terminal block
Electrical wire
18
Chapter 2 Installation / Connection