SDR/HDR Settings | 7
55
7.1.6 HLG_BT.2100
The relation between input signal (0 to 1023) and the brightness displayed on the monitor is
described below.
To display a HLG method gamma curve with a peak brightness of 1000 cd/m
2
compressed
on a monitor with a set brightness of 300 cd/m
2
, set "HLG Option" to "Off". To display
according to HLG method gamma curves uncompressed up to 300 cd/m
2
, and clipped from
300 cd/m
2
up, set to "HLG300".
• "HLG Option" : "Off"
0
100
200
300
400
500
600
700
800
900
1000
O
ut
pu
t Luminance
[cd
/m
²]
Input Code Value (10bit)
0
256
512
768
940 1023
HLG (1000 cd/m² target): YUV (64-940)
HLG (1000 cd/m² target): RGB (0-1023)
YUV (64-940)
RGB (0-1023)
• "HLG Option" : "HLG300"
0
100
200
300
400
500
600
700
800
900
1000
O
ut
pu
t Luminance
[cd
/m
²]
Input Code Value (10bit)
0
256
512
768
940 1023
777
832
HLG (1000 cd/m² target): YUV (64-940)
HLG (1000 cd/m² target): RGB (0-1023)
YUV (64-940)
RGB (0-1023)