Remedy
Check that the electrical supply is on, that the serial link is connected and that the
serial enable line is active.
Cause
Interface connection for RS232 or RS485 not working.
Remedy
Check that the electrical supply is on, that the serial link is connected and that the
serial enable line is active.
Check that the RS232 / RS485 control input is in the correct state.
Cause
Incorrect baud rate and node address.
Remedy
Check baud rate and, if operating in multi-drop mode, the node address matches those
of the pump.
Cause
Check that the red light is not on or flashing.
Remedy
If LED is on or flashing, perform the checks against the red alarm LED symptoms given
in
Table: Flashing error codes on page 77
Fault
Fail signal or standby signal not working
Cause
The serial enable line is not active.
Remedy
Must be disconnected or driven high for use of standby and fail lines.
Fault
Yellow service LED is flashing a repeated sequence
Cause
A service is necessary.
Remedy
Refer to
Service indicator codes on page 70
Fault
The red alarm LED is on
Cause
Normal during the software upgrade process. At other times indicates a problem has
been detected in the FLASH memory.
Remedy
If during software upgrade then complete the upgrade process. Otherwise cycle power
and if this does not help then perform a software upgrade.
Fault
The red alarm LED is flashing
Cause
A fail condition has activated.
Remedy
Note the position of the long flashes within the series of 6 flashes to work out the error
code.
Look up the flashing error code in
Table: Flashing error codes on page 77
and follow the
advice given.
Fault
The pump has failed to start or stop
Cause
The electrical supply has failed or the power LED does not flash.
Remedy
Check that the electrical supply voltage, fuses and frequency are correct according to
the power label.
Check that the power supply cable is fitted correctly into the electrical socket.
Page 73
A65901880_D - Fault finding
Содержание nRVi
Страница 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Страница 6: ...This page has been intentionally left blank...
Страница 97: ...Page 93 A65901880_D Service...
Страница 98: ...This page has been intentionally left blank...
Страница 99: ...This page has been intentionally left blank...
Страница 100: ...edwardsvacuum com...