Maintenance plan
Check the oil level on a monthly basis.
Replace the oil every 3000 hours of operation, actual time for
replacement will be application dependent. The colour of the oil is a
good indication of the need to change.
The oil in the pump should be clear; if the oil is cloudy or discoloured,
it is contaminated with process vapours.
Inspect and clean the inlet filter on a yearly basis.
Inspect and clean the gas ballast control on a yearly basis.
Clean the oil level sight glass
Clean the oil level sight glass on a yearly basis.
Clean the motor fan cover and enclosure on a yearly basis.
Clean and overhaul the pump after every 15000 hours of operation.
Fit new blades after every 30000 hours of operation.
Replace the pump controller after 10 years of operation.
An electrical safety check must be carried out in accordance with local
regulations for the periodic testing of electrical equipment.
7.2.1 Check the oil level
Note:
If required, the oil level can be checked while the pump is operating. The pump must be
switched off and the pump and other components in the pumping system isolated from
the electrical supply before pouring oil into the pump.
Refer to
Figure: General view of the pump on page 12
:
1.
Check that the oil level in the oil level sight glass (6) is between the MAX and MIN
level marks on the bezel of the sight glass.
2.
If the oil level is near to or below the MIN level mark, remove one of the oil filler
plugs (4) and pour more oil into the reservoir until the oil reaches the MAX level
mark. If the oil level goes above the MAX mark, remove the oil drain plug (7) and
drain the excess oil from the pump. Refit the filler plug.
Page 65
A65901880_D - Maintenance
Содержание nRVi
Страница 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Страница 6: ...This page has been intentionally left blank...
Страница 97: ...Page 93 A65901880_D Service...
Страница 98: ...This page has been intentionally left blank...
Страница 99: ...This page has been intentionally left blank...
Страница 100: ...edwardsvacuum com...