Cause
The inlet filter is blocked.
Remedy
Clean or replace the inlet filter.
Cause
The pump has not warmed up.
Remedy
Warm the pump to operate at an ambient temperature range (12 °C ~ 40 °C).
Fault
The pump is noisy
Cause
The motor fan cover is damaged or the motor bearings are worn.
Remedy
Return the pump to our service centre for repair.
Cause
The oil is contaminated with solid particles.
Remedy
Clean the pump and replace the oil.
Fault
The pump surface temperature is above 100 °C
Cause
The ambient temperature is too high.
Remedy
Set the ambient temperature to less than 40 °C.
Cause
The cooling air supply is insufficient or is too hot.
Remedy
Increase the air supply to an acceptable level and check that the ambient temperature
is less than 40 °C.
Cause
The outlet filter or the outlet pipeline is blocked.
Remedy
Clear the exhaust path.
Replace or clear the exhaust filter (if fitted).
Cause
The oil level is below the minimum allowable level.
Remedy
Fill the pump with oil above the minimum allowable level.
Cause
The pump has been filled with the wrong type of oil or the oil is contaminated.
Remedy
Clean the pump and replace the oil.
Cause
The process gas is too hot or the throughput is too high.
Remedy
Cool down the process gas.
Fault
The vacuum is not fully maintained after the pump is switched off
Cause
The gas ballast control is open.
Remedy
Close the gas ballast control.
Cause
The inlet valve pad is damaged.
Remedy
Replace the inlet valve.
Cause
The inlet valve has not closed.
Remedy
Close the inlet valve.
Page 75
A65901880_D - Fault finding
Содержание nRVi
Страница 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Страница 6: ...This page has been intentionally left blank...
Страница 97: ...Page 93 A65901880_D Service...
Страница 98: ...This page has been intentionally left blank...
Страница 99: ...This page has been intentionally left blank...
Страница 100: ...edwardsvacuum com...