![Edwards nRVi Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/edwards/nrvi/nrvi_instruction-manual_2366141034.webp)
Object
name
Command
Parameter
range
Factory
setting
Data type
Units
Comments
Standby
speed
setting
?S805
!S805
67..100
83
Decimal
%
Standby speed of
pump: Percentage (%)
of full mechanical
speed (see 801) ! S
stores standby speed to
non- volatile memory
(use !C805 for real-time
speed control, faster
execution and extended
non- volatile memory
life)
!C805
-
-
!C retains value in
volatile memory only
Auto run
?S806
!S806
0
1
0
Decimal
-
Run the pump system
from power on:
Enable = 1
Disable = 0
Temperature
readings
?V808
0..150
-
Decimal
°C
Measured pump
temperature *
0..150
-
Decimal
°C
Measured pump
controller temperature
*
Link
parameter
readings
?V809
0..5000
-
Decimal
0.1 V
Measured link voltage
± 0..300
-
Decimal
0.1 A
Measured motor
current
± 0..15000
-
Decimal
0.1 W
Measured motor power
Run hours
?V810
0..99999
~11 years
-
Decimal
Hours
Total run hours - time
pump has run
Pump cycles
?V811
0..99999
-
Decimal
Cycles
Total number of start/
stop cycles
Drive run
time
?V813
0..99999
~11 years
-
Decimal
Hours
Total run hours - time
pump controller has
run
0..99999
~11 years
-
Decimal
Hours
Hours until
recommended
controller replacement
Time run
since last
clean and
overhaul
service
?V814
0..99999
~11 years
-
Decimal
Hours
Number of pumps
running hours since last
clean and overhaul
service
Run time to
clean and
0..99999
~11 years
-
Decimal
Hours
Number of pumps
running hours left until
Page 30
A65901880_D - Technical data
Содержание nRVi
Страница 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Страница 6: ...This page has been intentionally left blank...
Страница 97: ...Page 93 A65901880_D Service...
Страница 98: ...This page has been intentionally left blank...
Страница 99: ...This page has been intentionally left blank...
Страница 100: ...edwardsvacuum com...