PROGRAMMING - SYSTEM OPTIONS
3-40
COMM Menu
The communications menu allows the operator to program the Accusetter to download data
to, or receive communications from, an external device and ,with multiple check or
multiple fixture programs, to setup signals to buss to other columns.
NOTE: See section
4.4, Communication in the Advanced Operation section of the manual for additional
technical specification.
External Device Setup
1)
Rotate the enter button to display "COMM" and then press ENTER.
2)
RS-232 will display. Press the ENTER button.
3)
Rotate the ENTER button to select "DEVICE" and then press ENTER.
4)
Rotate the ENTER button to select "NO COMM", "PRINTER", or "DATA
COL" and then press ENTER.
5)
"DEVICE" will display. Rotate the ENTER button to display "BAUD" and
then press ENTER.
6)
Rotate the ENTER button to select 600, 1200, 2400, 4800, 9600, or 19,200 and
then press ENTER.
NOTE: The default baud rate is 600.
7)
"BAUD" will display. Rotate the enter button to display "STATION" and then
press ENTER.
NOTE: If multiple columns are daisy chained by the RS-232C connector then
communication to a specific column requires the identification of the column
by station number. Use the following procedure to program the column
"Station" number.
8)
"STAT" with a numerical value will display. Rotate the enter button to display
desired station number, 0 to 9, to identify the column and then press ENTER.
9)
"STATION" will display. Press the RST button to return to the system menu,
"COMM" will be displayed.
Содержание Accu-Setter II
Страница 2: ...A Accu Setter II User s Manual Edmunds GAGES...
Страница 16: ...2 3 2 3 Overall E9300Unit Figure 2 1 Accusetter II Basic Unit E9300...
Страница 18: ...2 5 Figure 2 2 Front Panel...
Страница 20: ...2 7 Figure 2 3 Rear Panel...
Страница 31: ...3 3 Front Mounting Foot Rear Mounting Bracket Figure 3 1 Base Feet Figure 3 2 Filter Regulator Mounting...
Страница 32: ...3 4 Figure 3 3 Air Connections For Air Gaging Application Only...
Страница 39: ...3 11 An example of various multipliers as related to diameter measurement follows...
Страница 40: ...3 12 The last consideration to complete the formula is the gaging function See examples below...
Страница 43: ...PROGRAMMING SINGLE CHECK MEASUREMENT 3 15...
Страница 44: ...PROGRAMMING SINGLE CHECK MEASUREMENT 3 16...
Страница 50: ...PROGRAMMING MULTIPLE CHECK MEASUREMENT 3 22...
Страница 51: ...PROGRAMMING MULTIPLE CHECK MEASUREMENT 3 23...
Страница 59: ...PROGRAMMING MULTIPLE FIXTURE MEASUREMENT 3 31...
Страница 60: ...PROGRAMMING MULTIPLE FIXTURE MEASUREMENT 3 32...
Страница 90: ...4 5 Figure 4 3 A E Block...
Страница 93: ...4 8 Figure 4 5 Input Output Jumpers...