PROGRAMMING - MULTIPLE FIXTURE MEASUREMENT
3-38
Fixture Names
1)
Rotate the ENTER button to display check name.
2)
Press ENTER button. "FXT 1" will display.
3)
Press enter button. The first character will flash. To change, rotate ENTER button left
or right until desired character displays.
4)
Press ENTER button to move to next character.
5)
Press the RST button twice when done. Fixture name will display.
6)
Press the RST button twice to display "FXT 1".
Defining Fixture 2, 3, or 4
1)
Rotate the ENTER button to display FXT 2, 3, or 4 and follow the same programming
procedure beginning with “Defining Fixture 1” section until all fixtures are
programmed.
Part Names
Note:The part name of the program can be renamed if desired to store in memory.
7)
Press RST button three times to display "DEFINE".
8)
Rotate the ENTER button to display "PART NAME".
9)
Press the ENTER button. "PART 1" will display.
10)
Press the ENTER button. The first character will flash. To change, rotate the ENTER
button left or right until desired character is displayed.
11)
Press the ENTER button to move to next character.
12)
Press the RST button once, when done. The programmed name will display.
13)
Press the RST button once. "NAMES" will display.
Save Program
1)
Press the RUN button. "CANCEL" will display.
2)
Rotate the ENTER button to display "SAVE".
3)
Press the ENTER button to save setup.
4)
Proceed to the Programming — System section of this manual.
Содержание Accu-Setter II
Страница 2: ...A Accu Setter II User s Manual Edmunds GAGES...
Страница 16: ...2 3 2 3 Overall E9300Unit Figure 2 1 Accusetter II Basic Unit E9300...
Страница 18: ...2 5 Figure 2 2 Front Panel...
Страница 20: ...2 7 Figure 2 3 Rear Panel...
Страница 31: ...3 3 Front Mounting Foot Rear Mounting Bracket Figure 3 1 Base Feet Figure 3 2 Filter Regulator Mounting...
Страница 32: ...3 4 Figure 3 3 Air Connections For Air Gaging Application Only...
Страница 39: ...3 11 An example of various multipliers as related to diameter measurement follows...
Страница 40: ...3 12 The last consideration to complete the formula is the gaging function See examples below...
Страница 43: ...PROGRAMMING SINGLE CHECK MEASUREMENT 3 15...
Страница 44: ...PROGRAMMING SINGLE CHECK MEASUREMENT 3 16...
Страница 50: ...PROGRAMMING MULTIPLE CHECK MEASUREMENT 3 22...
Страница 51: ...PROGRAMMING MULTIPLE CHECK MEASUREMENT 3 23...
Страница 59: ...PROGRAMMING MULTIPLE FIXTURE MEASUREMENT 3 31...
Страница 60: ...PROGRAMMING MULTIPLE FIXTURE MEASUREMENT 3 32...
Страница 90: ...4 5 Figure 4 3 A E Block...
Страница 93: ...4 8 Figure 4 5 Input Output Jumpers...