3-7
3.3 Programming
Choose The Proper Program For Your Application:
1) Single-check — One feature is to be measured.
2) Multiple check — Up to four features are to be measured using one gage or fixture.
3) Multiple fixture — Up to four different gages may be used.
How To Select The Type Program The First Time:
1)
Turn power on with toggle power switch in rear of unit, after the power cord has been
hooked-up.
2)
Press RST button while "ACCUSETTER" is scrolling in the LED display.
3)
The display will read "CHG PRG?" (change program).
4)
Press the enter button and rotate until desired program is displayed, single check
("SNGL CHK"), multiple check ("MPL CHK"), and multiple fixture ("MPL FXT").
5)
Press the ENTER button again to select the program you need.
6)
Accusetter will scroll "PERFORM ACCUSETTER SETUP" or the program
description.
a)
If a different program type is being selected from that previously stored,
"PERFORMING ACCUSETTER SETUP" will Scroll until the ENTER button is
pressed. The Accu-Setter will then display "SETUP". Continue with programming.
b)
If the same type program is being selected, the Accu-Setter software S/N version &
program description will scroll and go automatically into the run mode after a (10)
second delay. If the Accu-Setter displays the type of program you want, but has not
been programmed for your application, you may need to change the program for
your application. To do that, press enter button. The Accu-Setter will display
"SETUP". Continue with programming.
Содержание Accu-Setter II
Страница 2: ...A Accu Setter II User s Manual Edmunds GAGES...
Страница 16: ...2 3 2 3 Overall E9300Unit Figure 2 1 Accusetter II Basic Unit E9300...
Страница 18: ...2 5 Figure 2 2 Front Panel...
Страница 20: ...2 7 Figure 2 3 Rear Panel...
Страница 31: ...3 3 Front Mounting Foot Rear Mounting Bracket Figure 3 1 Base Feet Figure 3 2 Filter Regulator Mounting...
Страница 32: ...3 4 Figure 3 3 Air Connections For Air Gaging Application Only...
Страница 39: ...3 11 An example of various multipliers as related to diameter measurement follows...
Страница 40: ...3 12 The last consideration to complete the formula is the gaging function See examples below...
Страница 43: ...PROGRAMMING SINGLE CHECK MEASUREMENT 3 15...
Страница 44: ...PROGRAMMING SINGLE CHECK MEASUREMENT 3 16...
Страница 50: ...PROGRAMMING MULTIPLE CHECK MEASUREMENT 3 22...
Страница 51: ...PROGRAMMING MULTIPLE CHECK MEASUREMENT 3 23...
Страница 59: ...PROGRAMMING MULTIPLE FIXTURE MEASUREMENT 3 31...
Страница 60: ...PROGRAMMING MULTIPLE FIXTURE MEASUREMENT 3 32...
Страница 90: ...4 5 Figure 4 3 A E Block...
Страница 93: ...4 8 Figure 4 5 Input Output Jumpers...