Operation
Page 57
The menu system is divided into two sections selectable from the
Home Screen
: The
Quick Menu
and
the
Main Menu
. The
Quick Menu
contains all information and operations necessary during scheduled
maintenance visits. The
Main Menu
contains all fields that are accessible to the users. It provides
information on component failures and measurement parameters as well as editable fields and test
procedures.
In general, editable parameters are displayed in bold font. Non-editable information is displayed in a
thin font. Some parameters may become editable based on the state of the instrument.
For example, the manual calibration type and mode can only be changed when the instrument has
finished the warm-up process.
3.4.1
Quick Menu
The
Quick Menu
contains all the maintenance tools in one easy to use screen. It allows operators to
perform calibrations, check important parameters and review the service history.
Figure 43
–
Quick Menu Screen
Span Calibrate CO
This field is used to perform a span calibration adjustment and
should be only used when a known concentration of span gas is
being drawn through the measurement cell and the reading is
stable.
Activating the span calibrate field for a named gas will open a
dialog box. Enter the concentration of the span gas that the
instrument is sampling and press
Accept
.
Event Log
This field enters a screen with a log of all the events that the
instrument has performed. These events include errors and
warnings. This log is stored on the removable USB memory stick.
The log is organised by month. When the user enters this screen,
they will be prompted to enter the month for which they wish to
view the events.
Instrument
This field allows the instrument to be set to either
Online
(normal
instrument operation) or In
Maintenance
(data is flagged as
invalid).
Safely Remove USB Stick
Always select this menu item before removing the USB memory
stick or select the same menu item from the
Service Menu
(refer
to Section 3.4.13). Failure to do this may cause corruption of the
memory stick.
Содержание Acoem Serinus 30
Страница 2: ...Serinus 30 User Manual 3 3 Page 2 This page is intentionally blank...
Страница 20: ...Serinus 30 User Manual 3 3 Page 20 This page is intentionally blank...
Страница 38: ...Serinus 30 User Manual 3 3 Page 38 Figure 22 Received Item...
Страница 118: ...Serinus 30 User Manual 3 3 Page 118 This page is intentionally blank...
Страница 138: ...Serinus 30 User Manual 3 3 Page 138 This page is intentionally blank...
Страница 144: ...Serinus 30 User Manual 3 3 Page 144 Figure 131 Avoid to Touching Particulate Filter Paper...
Страница 157: ...Serinus 30 User Manual 3 3 Page 157 This page is intentionally blank...
Страница 162: ...Serinus 30 User Manual 3 3 Page 162 7 1 Flow Fault Figure 142 Flow Fault Diagnostic Procedure Section 2 3 2 Section 5 2...
Страница 165: ...Troubleshooting Page 165 7 4 Mirror Temperature Failure Figure 145 Mirror Temperature Failure Diagnostic Procedure...
Страница 166: ...Serinus 30 User Manual 3 3 Page 166 7 5 USB Memory Stick Failure Figure 146 USB Memory Stick Failure...
Страница 169: ...Serinus 30 User Manual 3 3 Page 169 This page is intentionally blank...
Страница 192: ...Serinus 30 User Manual 3 3 Page 192 9 5 Plumbing Schematic PN D020005...
Страница 193: ...Parts List and Schematics Page 193 9 6 Block Wiring Schematic PN D020102...
Страница 194: ...Serinus 30 User Manual 3 3 Page 194 9 7 Measurement Cell PN H014100...
Страница 195: ...Parts List and Schematics Page 195 9 8 Source Timing Assembly PN H014125...
Страница 196: ...Serinus 30 User Manual 3 3 Page 196 9 9 Calibration Manifold Assembly PN H010013 01...
Страница 197: ...Parts List and Schematics Page 197 9 10 Valve Assembly PN H010042...
Страница 198: ...Serinus 30 User Manual 3 3 Page 198 9 11 High Pressure Valve Exploded View PN H050043...
Страница 199: ...Parts List and Schematics Page 199 9 12 Sample Filter Holder Assembly PN H010160...
Страница 200: ...Serinus 30 User Manual 3 3 Page 200 9 13 CO CO2 Converter Assembly PN H014130...
Страница 201: ...Serinus 30 User Manual 3 3 Page 201 This page is intentionally blank...