Security distances should be respected when the boiler is installed in spaces where materials, either
construction materials or those surrounding the boiler, are likely to be flammable.
4.22.
If the floor is made of a combustible material, install a fire protection between the floor and the boiler.
Drawing 8
EXAMPLES OF FLUE INSTALLATIONS.
Although we cannot keep track of or describe every single installation, option, or the local installation
regulations corresponding to your area, Ecoforest guarantees that the installations suggested below will enable
your boiler to function properly, and to conform to minimum personal and material safety measures.
If you are installing your boiler in a building, in addition to respect local regulations on gas flues, you
should consult with the residents’ association to avoid future problems.
Please read the entire manual carefully, especially the chapter on installation to ensure your boiler
operates properly and at full power.
4.28.
The installation shown below is the most common. Please bear in mind that if the gas flue pipe located on
the outside of the dwelling is in an area where people pass by, insulated tube must be used.
Drawing 9
A
Lateral wall.
≥ E
B
Back of the boiler.
≥ 100 mm
C
Total depth with doors open.
See dimensions
D
Shelf.
≥ 1500 mm
E
Depth of boiler.
See dimensions
Windbreak.
Stainless steel hose clamp.
T of 135° with outlet.
Elbow of 45°.
Insulator.
Wooden ground.
Non flammable floor protection.
*Distance equal to or less than 2 metres.
*
If the tube over 4 m in length, the next larger
size will be used.