37
Drawing 12
HEATING SYSTEM DRAINING (VERY IMPORTANT).
To access the purgecock, we must remove the cap of the liner covering it and the safety thermostat. It is
located in the upper left side of the boiler. It is important to note that the purge should be performed by an
authorized installer.
Drawing 13
WI-FI ANTENNA CONNECTION, POWER CABLE, ROOM THERMOSTAT, KEYBOARD AND KEYBOARD SUPPORT.
The boiler is supplied with a
Ecoforest
box. This box contains the user manual, the installation and
maintenance manual, a power cable, a room sensor, a cleaning brush, a Wi-fi antenna.
The user has to attach the wi-fi antenna and module to the connection platform (check section
1
of the
tablet manual). The connection platform of the wi-fi antenna is supplied attached to the rear of the hopper.
The room sensor and power cable must be connected to the rear heaters, in the right-hand side of the boiler.
Drawing 14
Heat flow. (See technical features).
Heating return. (See technical features).
Safety valve discharge. (See technical
features).
Charge-discharge. (See technical features).
Drain siphon.
Normally closed valve
Water main.
Purger.
Power connection
~
230/240V - 50Hz.
Thermostat connection.
Содержание VAP 30
Страница 2: ...1 ...
Страница 125: ...124 8 ESQUEMA ELÉCTRICO ELECTRICAL DRAWING SCHEMA ELÉCTRIQUE SCHEMA ELETTRICO ESQUEMA ELÉCTRICO ...
Страница 127: ...126 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS VAP 30 CG 00 04 UNE EN 303 5 ...
Страница 131: ...130 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS VAP 38 CG 00 04 UNE EN 303 5 ...