45
6.9.
Make sure the gas outlet tube is not obstructed by anything (e.g. bird nest, plastic, etc.).
6.10.
Make sure the exhaust motor works, because if it does not work fuel will not fall.
6.11.
With the boiler unplugged
, check that the safety thermostat is located at the back, to the right side of the
boiler. To activate it, you must unscrew the cap and press the button if necessary. If the thermostat is
activated you will hear a “click”. If the safety thermostat had been activated before, consult your dealer.
Drawing 26
shows where the thermostat is located in the
Cantina Nova
and
Aveiro
models. The safety
thermostat in the
Super Insert
model can be found at the upper side of the lining.
Drawing 29
6.12.
If the reducer motor receives current and rotate slower than usually, it may have something blocked such as
a screw, a piece of wood, etc. To solve this problem, you must empty the hopper and, even if necessary, to
remove the auger screen.
6.13.
If when the reducer motor rotates makes a noisy is due to a lack of lubrication- you have to lubricate only the
auger screen,
not the reducer motor
, see point
5.12
.
PELLETS FALL BUT THE BOILER DOES NOT TURN ON:
6.14.
Make sure the door is well closed.
6.15.
Check that the resistance is properly placed. That is, the resistance support tube coincides with the largest
centre hole in the burn pot. Similarly, the resistance support tube must abut the burn pot.
Drawing 30
Safety thermostat.
Burn pot.
Resistance air inlet.
Resistance drive.
Start-up resistance.
Resistance tube support.
Screw of resistance.
Resistance support guide.
Resistance support tube, badly fixed.
Resistance support tube, badly fixed.
Start-up resistance, badly fixed.
Resistance support tube; badly fixed.
Содержание VAP 30
Страница 2: ...1 ...
Страница 125: ...124 8 ESQUEMA ELÉCTRICO ELECTRICAL DRAWING SCHEMA ELÉCTRIQUE SCHEMA ELETTRICO ESQUEMA ELÉCTRICO ...
Страница 127: ...126 10 MEDIDAS MEASURES MESURES MISURES MEDIDAS VAP 30 CG 00 04 UNE EN 303 5 ...
Страница 131: ...130 12 MEDIDAS MEASURES MESURES MISURES MEDIDAS VAP 38 CG 00 04 UNE EN 303 5 ...