background image

Baxi Avanta Plus

18s - 24s - 30s

24c - 28c - 35c - 39c

User’s Operation Instructions &

High-efficiency wall-hung boilers

Important Warranty Information

United Kingdom

en

Please keep these instructions in a safe place.
If you move house, please hand over to the next occupier.

Summary of Contents for Baxi Avanta Plus 18s

Page 1: ...24c 28c 35c 39c User s Operation Instructions High efficiency wall hung boilers Important Warranty Information United Kingdom en Please keep these instructions in a safe place If you move house please hand over to the next occupier ...

Page 2: ...d safe and efficient operation we recommend that the product is regularly maintained Our Service and After Sales organization can assist with this We hope you will receive many years of satisfactory service A Trading Division of Baxi Heating UK Ltd 3879156 Brooks House Coventry Road Warwick CV34 4LL After Sales Service 0844 871 1525 Technical Enquiries 0844 871 1555 Website www baxi co uk ...

Page 3: ... 3 1 Safety 4 1 1 General safety 4 1 2 Safety during operation 4 2 Problems with boiler and or central Heating system 5 2 1 Error codes errors which can be resolved by the user 5 2 2 Error codes errors which have to be remedied by the installer 5 3 Changing boiler settings 6 3 1 Changing P1 setting flow temperature of water in central heating system 6 3 2 Changing P2 setting domestic hot water tem...

Page 4: ...ave the building together Call your gas suppliers installer once you are outside the building TRANSCO tel 0800 111 999 Warning Can you smell smoke or flue gases What to do Switch off the boiler Open windows and doors Warn those present and leave the building together Call your installer once you are outside the building Warning Installation location for the boiler Do not store or use any flammable...

Page 5: ...ne with gas supply pipe if necessary open gas valve Press R key Wait for recovery display shows 0 boiler functions properly Display shows e4 again note down the error code and boiler type and call your installer Or Or e7 Display shows e1 e2 e7 e9 or e10 again note down the error code and boiler type and call your installer e10 e1 e9 Fig 1 Errors which can be resolved by the user LT NL W6H 000 114 ...

Page 6: ... K1 are displayed alternately Press key until codes pK and K2 are displayed alternately Press Enter key set value for domestic hot water temperature is displayed 55 C factory setting Press or key to change this value for example to 65 C Press Enter key to confirm value codes pK and K2 are displayed alternately Press Reset key to switch boiler to operating mode 3 Changing boiler settings 3 1 Changi...

Page 7: ...ependent factory setting Press key to change this mode for example mode 1 eco mode Press Enter key to confirm this mode codes pK and K4 are displayed alternately Press Reset key to switch boiler to operating mode 3 5 Changing P6 setting display on off Change the display setting as follows Press Enter key until codes pK and K1 are displayed alternately Press key 5x until codes pK and K6 are display...

Page 8: ...etention function Now the boiler will only start working to protect itself against freezing With an external frost protection connected the boiler can also prevent the central heating system from freezing Pre and After Sales Service Our dedicated pre and after sales teams are ready te give you the support you need Its an integral part of the quality package that Baxi offers as standard with all pr...

Page 9: ...play K1 pre purge stage K2 ignition stage K3 operating in CH mode or K4 operating in DHW mode K7 pump run on after CH or DHW is satisfied K0 stand by mode Set the room thermostat to the desired room temperature The boiler will now automatically start operating 5 Enabling the boiler Check the boiler water pressure If the water pressure is less than 1 bar the system has to be topped up with water 2 ...

Page 10: ...iler and he she can t repair it our friendly customer service team is on hand to help Simply call our service division heateam on 0844 871 1525 to book an engineer visit or for any general advise that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling heateam it would be helpful if you could ...

Page 11: ...f complying with the appropriate Building Regulations England and Wales All installations must be notified to Local Area Building Control either directly or through a Competent Persons Scheme A Building Regulations Compliance Certificate will then be issued to the customer who should on receipt write the Notification Number on the Benchmark Checklist This product should be serviced regularly to op...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ...chnological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior consent in writing Subject to alterations ...

Page 16: ...ading Division of Baxi Heating UK Ltd 3879156 Brooks House Coventry Road Warwick CV34 4LL After Sales Service 0844 871 1525 Technical Enquiries 0844 871 1555 Website www baxi co uk 7604251 7604251 v 01 08052013 ...

Reviews: