EN 50065-1 measurements. One limit is measured using a quasi-peak detector,
the other using an average detector. Note that those limits are the same as
required for any other CENELEC compliant product, except in the
communication range of 110kHz to 140kHz where lower noise levels are
specified.
For FCC applications, the limit of figure 5.8 corresponds to FCC Class B limits
for frequencies above 450kHz. Below 450kHz, the limits are set such that the
full communication performance of the PLT-22 transceiver is maintained. Two
lines are indicated. The solid "single carrier" line shows the noise limits required
to maintain full performance if the transceiver is used only in its single carrier
frequency mode. If the PLT-22 transceiver is going to be used in its dual carrier
frequency mode, then it is recommended that the power supply noise fall below
the dashed "dual carrier" line. Meeting this criteria ensures that the full
performance of both operating frequencies is available to overcome unexpected
power line noise in either of the two frequency ranges. A quasi-peak detector
should be used when verifying power supply noise against the limit lines of
figure 5.8.
For both CENELEC and FCC measurements, the measurement bandwidths are
200Hz for measurements below 150kHz, and 9kHz for measurements above
150kHz, as described in CISPR 16.
L
ON
W
ORKS
PLT-22 Transceiver's User Guide
5-13
Содержание LONWORKS PLT-22
Страница 6: ...iv Echelon...
Страница 14: ...1 8 Introduction...
Страница 67: ...LONWORKS PLT 22 Transceiver s User Guide 5 7 Figure 5 3 Capacitor Input Power Supply Schematic...
Страница 92: ...6 10 Design and Test for Electromagnetic Compatibility...
Страница 110: ...7 18 Communication Performance Verification...
Страница 114: ...8 4 References...
Страница 118: ...A 4 Appendix A...