![Echelon LONWORKS PLT-22 Скачать руководство пользователя страница 108](http://html1.mh-extra.com/html/echelon/lonworks-plt-22/lonworks-plt-22_user-manual_3897121108.webp)
Table 7.1
Primary Frequency Receive Performance Verification Table
Send
Transmit
Attenuatio
n (PLCA
Attn)
Overall
Attenuatio
n (Attn +
60)
UnackPr
i Error %
(expecte
d)
UnackPr
i Error %
(observe
d)
UUT Pkts
Received
(observed)
UUT
Error %
(expected)
UUT
Error %
(1011 - #Rcvd)/10
(observed)
0 dB
60 dB
<1%
<1%
6 dB
66 dB
<2%
<2%
12 dB
72 dB
<3%
<3%
18 dB
78 dB
≥
3%
≥
3%
24 dB
84 dB
≥
3%
≥
3%
Table 7.2
Secondary Frequency Receive Performance Verification Table
Send
Transmit
Attenuatio
n (PLCA
Attn)
Overall
Attenuatio
n (Attn +
60)
UnackSe
c Error %
(expecte
d)
UnackSe
c Error %
(observe
d)
UUT Pkts
Received
(observed)
UUT
Error %
(expected)
UUT
Error %
(1011 - #Rcvd)/10
(observed)
0 dB
60 dB
<1%
<1%
6 dB
66 dB
<3%
<3%
12 dB
72 dB
≥
3%
≥
3%
18 dB
78 dB
≥
3%
≥
3%
The approximate signal attenuation between the Send PLCA-22 analyzer and Recv
PLCA-22 analyzer shown in tables 7.1 and 7.2 is the sum of the attenuation level of
the attenuator circuit and the
Attn
level of the Send PLCA-22 analyzer. A properly
performing product will show a low level of CRC errors (<3%) up to an attenuation of
72dB between the two analyzers (66dB for secondary frequency). Above these
attenuations the error rate for the UUT should increase.
If the results of this test are worse than expected, it is helpful to know if the problem
affects only the performance of the UUT or if adjacent receivers are also impaired by
the presence of UUT. If the receive performance of the Recv PLCA-22 analyzer was
worse than expected, disconnect the UUT and recheck the PLCA-22 analyzer error
rate versus attenuation. If it is determined that the presence of the UUT impairs the
performance of the PLCA-22 analyzers then the UUT may be injecting noise back
onto the power line. Note that the same symptoms would also be observed if no
7-16
Communication Performance Verification
Содержание LONWORKS PLT-22
Страница 6: ...iv Echelon...
Страница 14: ...1 8 Introduction...
Страница 67: ...LONWORKS PLT 22 Transceiver s User Guide 5 7 Figure 5 3 Capacitor Input Power Supply Schematic...
Страница 92: ...6 10 Design and Test for Electromagnetic Compatibility...
Страница 110: ...7 18 Communication Performance Verification...
Страница 114: ...8 4 References...
Страница 118: ...A 4 Appendix A...