![Echelon LONWORKS PLT-22 Скачать руководство пользователя страница 116](http://html1.mh-extra.com/html/echelon/lonworks-plt-22/lonworks-plt-22_user-manual_3897121116.webp)
PLT-22 Transceiver Isolation Transformer Schematic
1
2
3
4
Primary
Secondary
PLT-22 Transceiver Isolation Transformer Electrical
Specifications
Below are specifications for the PLT-22 Transceiver Isolation Transformer Schematic
shown above.
Parameter Min
Typ
Max
Units
Turns Ratio (1-2) : (3-4)
1.0
DC Resistance
1-2
3-4
0.20
0.20
Ohm
Ohm
Magnetizing Inductance 1-2
Dry, @100kHz, 1Vrms
0.75 1.0 1.25 mH
Magnetizing Inductance 1-2,
Wet, @100kHz, 1Vrms,
plus15mADC
0.75
mH
Leakage Inductance 1-2
(3-4 shorted) @100kHz, 1Vrms
10.8 12.0 13.2 µH
Winding Capacitance 1-2
30
pF
Winding to Winding Capacitance
1-2 shorted to 3-4 shorted
30
pF