PLT-22 Transceiver Electrical Specifications
Table 2.2 lists the electrical specifications of the PLT-22 transceiver when used in
the 110kHz – 140kHz frequency range. All specifications apply over the full
operating temperature and supply voltage ranges unless otherwise indicated.
Table 2.2
PLT-22 Transceiver Electrical Specifications
Parameter
Min Typ
Max Units
Operating temperature range1
-40 +85
°
C
V
DD5
input supply voltage
4.75
5
5.25
Volts
V
A
input supply voltage
TXLVL = open
8.5
9.7
16
Volts
TXLVL = GND2
11.4
12.0 16
Volts
I
DD5
input supply current
(not including PKD and BIU LED Current)
receive
16
23
mA
transmit
13
18
mA
I
A
input supply current
receive
4 6
mA
transmit
130
250
mA
TXOUT signal level: TXLVL=open, into 50
Ω
load
3.6
Volts p-p
TXOUT signal level: TXLVL=GND, into 50
Ω
load
7
Volts p-p
Output current limit
1.0
Amps p-p
Output impedance, in-band (transmit)
0.9
1.1
Ohms
Input impedance, in-band (receive)
500
Ohms
PKD output source current @ V
DD5
-0.6 V
8
mA
BIU output source current @ V
DD5
-0.6 V
8
mA
Power management, lower threshold
7.2
7.9
8.5
Volts
Power management, upper threshold
11.1
12.0
12.9
Volts
Notes:
1. Maximum operating temperature is a function of V
A
supply voltage and the maximum
transmission duty cycle for the node. A maximum operating temperature of 85°C is
specified for a V
A
supply
≤
12.6V and a maximum transmit duty cycle of 65%, which is
the maximum achievable with LONMARK interoperable transceiver parameters and
messages of
≤
34 Bytes. For other cases see figure 2.2.
2. While operating in the 7V p-p mode (TXLVL = GND), the V
A
supply must not drop below
11.4V under conditions of typical line voltage, room temperature, and typical current drain
(including the PLT-22 transceiver’s typical I
A
transmit current of 130mA). This condition
ensures adequate transmit amplifier headroom to drive the full 7Vp-p signal
2-4
Using
the
PLT-22
Transceiver
Содержание LONWORKS PLT-22
Страница 6: ...iv Echelon...
Страница 14: ...1 8 Introduction...
Страница 67: ...LONWORKS PLT 22 Transceiver s User Guide 5 7 Figure 5 3 Capacitor Input Power Supply Schematic...
Страница 92: ...6 10 Design and Test for Electromagnetic Compatibility...
Страница 110: ...7 18 Communication Performance Verification...
Страница 114: ...8 4 References...
Страница 118: ...A 4 Appendix A...